Automatic Tracking and Positioning Jet Fire Water Cannon 5L

The ZDMS0.6/5S-LZⅢ 5 L/s Automatic Fire Monitor is an automatic tracking and positioning fire water cannon designed for warehouses, factories, and other large indoor spaces. Featuring thermal imaging fire detection, automatic targeting, a built-in valve, and a fully sealed housing, it provides a 20 m protection radius and supports integration with fire water supply and control systems.

Brand:
LinkZone
SKU:
ZDMS0.6/5S-LZⅢ
Certification:
HS250122, ICR, VC
Rated Flow:
5 L/s
Protection Radius:
20 m
Monitoring Radius:
40 m
Ready
ZDMS0.6/5S-LZIII compact 5 L/s automatic fire monitor with integrated valve

Automatic Tracking & Positioning

Compact 5 L/s Automatic Fire Monitor

Model: ZDMS0.6/5S-LZⅢ

Designed for large-space fire protection, this compact automatic fire monitor combines fire-source detection, automatic tracking, precise aiming and water discharge in a sealed housing with an integrated valve. Its streamlined design suits warehouses, factories, logistics centres and other high-ceiling facilities, subject to project-specific system design and local requirements.

Large-Space
Protection
Automatic
Tracking
Integrated Valve
& Sealed Design

Product Structure & Key Zones

Five construction details of the ZDMS0.6/5S-LZⅢ compact automatic fire monitor.

1

Integrated Control Valve

The LZⅢ configuration incorporates its water-control valve within the monitor assembly, reducing the need for a separately mounted external valve.

2

Sealed Protective Housing

Enclosed construction helps shield the operating mechanism from dust and splashing water. A built-in filter is identified in the manufacturer’s product information.

Front view of ZDMS0.6/5S-LZIII compact automatic fire monitor with white sealed housing, top flange and black front detection nozzle assembly
3

Rotating Cable Arrangement

The compact rotating design is intended to limit cable twisting during horizontal movement. Confirm the supplied slip-ring configuration on the final technical drawing.

4

Short Nozzle Geometry

The nozzle remains within the compact housing envelope, helping reduce the risk of contact with nearby structures during rotation.

5

Fire-Source Detection Assembly

Thermal-imaging-based fire-source positioning is specified for this configuration. Sensor type and exact positioning are subject to the selected variant.

Numbered markers illustrate feature areas; internal valve and rotating electrical components are not visible in the exterior photograph. Use the approved manufacturer drawings to identify their exact locations.

Automatic Detection & Discharge

1

Detect Heat Source

Illustration of thermal fire-source detection

Fire-source sensing initiates a search when the configured detection conditions are met.

2

Locate & Track Fire

Illustration of fire-source targeting brackets

The configured sensing assembly locates the fire source and can update the target position as it changes.

3

Discharge Water

Compact fire monitor rotating to aim at the target

The monitor adjusts its orientation to direct the nozzle towards the located fire source.

4

Aim Automatically

Illustration of water discharge from a fire monitor

After the required control conditions and operator procedures are satisfied, the water-supply system enables discharge.

Illustrative operating sequence. Detection technology, control permissions and automatic discharge behavior depend on the selected configuration and commissioning settings. Images are conceptual illustrations, not exact component diagrams.

Need a system reference layout?

Ask FireMarket for a free preliminary design.

Warehouses
Factories
Logistics Centers
Other Large-Space Facilities

Fire Recognition & Targeting

Multi-sensor fire detection for more precise targeting and reduced false triggers.

FireMarket Recognition Technology

3-in-1 Precision Detection & Dynamic Tracking

UV Flame Detection IR Thermal Positioning VIS Visual Recognition

UV, infrared and visual inputs support fire-source localization, with moving-fire tracking available on supported configurations.

UV IR VIS

FireMarket 3-in-1 Recognition

Multiple sensing inputs help verify the fire location before discharge.

Single-Cue Recognition

Unverified visual cues may lead to false detection and unintended discharge.

✕ False Trigger Examples

false-trigger-screen

Flames on a Digital Screen

A flame video is mistaken for a real fire, causing unwanted discharge.

false-trigger-led

Red LED Warning Light

A warning light is mistaken for a flame, triggering an unwanted water discharge.

Illustrative false-trigger scenarios. Actual discharge depends on the configured detection and release logic.

Technical Parameters

ModelZDMS0.6/5S-LZⅢ
Flow Rate5 L/s
Protection Radius20 m
Monitoring Radius40 m
Installation Height6–15 m
Working Pressure0.6–0.8 MPa
Detection Time≤ 30 s

System Integration

Pairs with fire-water supply, field controls and a central control host for monitored, controlled water discharge and multi-monitor projects.

Water tank and pump illustration

Water Supply System

Tank · Pump · Pipework

Representative electric control box

Electric Control Box

Electrical control

Representative field operation panel

Field Operation Panel

On-site operation

Representative control host screen

Control Host

Centralized monitoring

Multi-monitor configurations for larger projects.

Accessories and environment requirements reviewed during selection.

Illustrative overview only. Red line shows system association, not piping or wiring order; follow the manufacturer’s drawings for installation.

Model ZDMS0.6/5S-LZⅢ
Rated Flow 5 L/s
Protection Radius 20 m
Monitoring Radius 40 m
Installation Height 6–15 m
Working Pressure 0.6–0.8 MPa
Detection Time ≤ 30 s
Water Inlet DN50
Reference Standard GB 25204-2010

PRODUCT & TECHNICAL SUPPORT

Automatic Tracking and Positioning Jet Fire Water Cannon 5L FAQs

Frequently asked questions about this product, configuration, compatibility and technical requirements.

01. What is the ZDMS0.6/5S fire monitor?

It is a fixed firefighting water monitor, also commonly described as a fire water cannon or water jet fire suppression device, designed to direct a concentrated water stream toward a protected area.

02. What is the difference between the ZDMS0.6/5S-LZII and ZDMS0.6/5S-LZIII?

The LZII is identified as an external-valve water jet device, while the LZIII is identified as an integrated-valve automatic fire monitor. Automatic flame detection and positioning functions are confirmed for the LZIII but should not be assumed for the LZII without separate written confirmation.

03. What is the flow rate of the ZDMS0.6/5S fire water cannon?

Both the ZDMS0.6/5S-LZII and ZDMS0.6/5S-LZIII configurations have a specified flow rate of 5 L/s, equivalent to 300 L/min.

04. What protection radius does the 5 L/s fire monitor provide?

The specified protection radius is 20 m. Final coverage depends on verified hydraulic pressure, installation height, obstructions, nozzle orientation, and the approved fire protection layout.

05. What is the monitoring radius of the ZDMS0.6/5S models?

The specified monitoring radius is 40 m. Monitoring radius and water-jet protection radius are different parameters and should not be treated as the same coverage limit.

06. What installation height is specified for the ZDMS0.6/5S fire monitor?

The specified installation height range for both 5 L/s configurations is 6 to 15 m. The final mounting height must be confirmed through the approved hydraulic and fire protection design.

07. What working pressure is required by the ZDMS0.6/5S fire water cannon?

The LZII configuration is specified at 0.6 MPa, while the LZIII configuration is specified at 0.6 to 0.8 MPa. Use the value for the exact ordered model when sizing the water supply and pump system.

08. How quickly does the automatic fire monitor detect or scan for a fire?

The LZIII detection time is specified as no more than 30 seconds, while the LZII parameter table lists a scanning time of no more than 30 seconds. These terms apply to their respective configurations and do not define the total time required for water discharge or fire extinguishment.

09. Can the ZDMS0.6/5S-LZIII automatically detect and target a fire?

Yes. The LZIII supports automatic flame detection, scanning, positioning, aiming, alarm reporting, and water-discharge control when installed and commissioned as part of the complete approved system.

10. Does the automatic fire water cannon support manual control?

Yes. The LZIII can be aimed and controlled manually through the control host or field operation panel, providing an operator-controlled alternative to automatic operation.

11. Can the fire monitor be controlled remotely from a fire control room?

The LZIII system supports control through a central host located in the fire control room, with device status, addressing, manual aiming, valve control, pump control, and stop functions subject to the approved system configuration.

12. Can the ZDMS fire monitor rotate through 360 degrees?

The installation requirements call for unobstructed 360-degree rotation. The monitor must be mounted with sufficient clearance and enough cable allowance to prevent the structure or wiring from restricting movement.

13. How should the fire water cannon be mounted?

The standard configuration is installed vertically downward on a straight downward-facing pipe connection, with the upstream pipe securely fixed to a wall or steel structure. Alternative mounting arrangements require confirmation before ordering.

14. How much clearance is required around the ZDMS0.6/5S-LZIII?

Available LZIII installation information contains both 40 cm and 60 cm minimum-clearance instructions. Do not rely on the smaller value without confirmation; use the current approved installation drawing and obtain written confirmation for the project configuration.

15. What water supply equipment is required for the automatic fire monitor system?

The fire monitor must connect to a suitable firefighting water supply that may include a water tank, fire pumps, valves, pipework, and fittings. The required flow and pressure must be verified hydraulically, and the exact equipment included in the supply package should be confirmed before ordering.

16. Is a strainer required before the fire monitor valve?

Yes. An upstream strainer is required to reduce the risk of debris preventing the solenoid or electric valve from closing correctly. The water pipeline should also be flushed and pressure-tested before valve installation.

17. What field wiring does the fire water cannon system require?

The documented system uses a 4+2+1 field wiring concept consisting of four power conductors, two signal conductors, and one video path. Cable sizes, separation, polarity, routing, and voltage must follow the approved project wiring diagram.

18. How many fire monitors can connect to one control host?

The system can be arranged for multiple monitors, but when the total exceeds 32 devices, additional power and signal circuits are required. The LZIII configuration also calls for an additional control-host circuit board, so the final capacity must be confirmed during system design.

19. What is required when the LZIII video transmission distance exceeds 300 m?

For video transmission beyond 300 m, the LZIII configuration requires an optical-fiber link and a coaxial video optical terminal rather than relying only on the standard coaxial video cable.

20. What conditions can interfere with automatic flame detection?

Potential interference sources include open flames used during normal work, welding, large LED displays, direct sunlight, glass curtain walls, high-temperature objects, infrared or ultraviolet light sources, and strong electromagnetic fields. The project design and commissioning process must evaluate these conditions, and operators must confirm the event before enabling water discharge where required by the approved operating strategy.

21. Can the ZDMS0.6/5S fire monitor discharge foam?

Foam compatibility is not confirmed for these documented configurations. Do not specify foam concentrate, foam solution, or mixed water-and-foam service without written confirmation covering the exact monitor, valve, nozzle, seals, and system design.

22. Can the ZDMS0.6/5S fire water cannon be installed outdoors?

No outdoor or weatherproof rating is confirmed for these configurations. Installation conditions, enclosure protection, corrosion exposure, temperature limits, and any required weather protection must be verified before outdoor use.

23. What certifications apply to the ZDMS0.6/5S-LZII and LZIII fire monitors?

No specific product certification or approval standard is confirmed for these documented configurations. Request the applicable certificate for the exact model, valve arrangement, and destination market when project approval is required.

24. How often should the automatic fire monitor be inspected and tested?

Manufacturer guidance suggests weekly manual operation checks and monthly checks of automatic and remote-control functions, with cleaning and lubrication adjusted for site dust conditions. These are product recommendations only; actual inspection, functional testing, water-discharge testing, and maintenance must follow applicable local regulations, the approved system design, site conditions, and the approved maintenance plan.

Free Preliminary System Drawings

Working on a project budget without a system layout? FireMarket provides free preliminary drawings to help you estimate equipment quantities and costs.

Request Free Preliminary Drawings