Conventional Sounder Strobe

The TXC7301 Conventional Sounder Strobe combines a pulsing audible alarm with a flashing LED strobe in a compact 24 V DC device. It operates on a compatible conventional fire alarm output without device-address programming.

Brand:
Tanda UK
SKU:
TXC7301
Certification:
CE, CPR, TUV
SPL:
80–100 dB @ 3 m

TXC7301

Conventional Sounder Strobe

When energised, the TXC7301 alerts occupants with a pulsing audible alarm and a flashing LED strobe. The compact field device is designed for a 24 V DC conventional fire alarm system and requires no device address programming.

TXC7301 conventional sounder strobe with red lens and white base

Audible and Visual Fire Alarm Notification

Pulsing Audible Alarm

The audible output rises over the first 3–5 seconds after activation. The manual specifies 75–105 dB measured at 3 m in front of the unit.

High-Intensity LED Strobe

A bright, low-power LED cluster provides a distinct visual cue alongside the audible warning.

Compact, Non-Coding Design

The circular enclosure is 100 mm in diameter and 44 mm deep with its mounting base. The device operates when its compatible conventional alarm output supplies power.

See Both Alarm Outputs Activate

Start the demonstration to see the sounder and LED strobe activate together.

Standby
TXC7301 sounder strobe shown in the demonstration

Sounder

Standby

LED strobe

Standby

Silent visual demonstration. Light and sound indicators are illustrative.

Mounting and Applications

Separate Mounting Base

The installation drawing shows the sounder strobe seated on its base over an embedded wall box. The wiring terminals are accessed at the back of the unit.

Conventional Alarm Output

Use a compatible 24 V DC conventional alarm output and observe the terminal polarity shown in the installation manual.

Commercial and Facility Applications

Typical sites include hotels, restaurants, office buildings, banks, shopping malls, warehouses, computer rooms, museums and libraries.

Technical Specifications

Operating voltage
24 V DC nominal (15–28 V DC)
Starting current
<10.0 mA
Sound pressure level
75–105 dB at 3 m
Strobe flash frequency
1.0–1.8 Hz
Sound pulse timing
2.5–4.5 s
Operating temperature
−10°C to +50°C
Relative humidity
≤95% RH, non-condensing
Size and weight with base
Ø100 × 44 mm · approx. 108 g

PRODUCT & TECHNICAL SUPPORT

Conventional Sounder Strobe FAQs

Frequently asked questions about this product, configuration, compatibility and technical requirements.

01. What is the TXC7301 Conventional Sounder Strobe?

The TXC7301 is a conventional, non-addressable alarm notification device that combines an audible sounder with flashing LED indication for use in a fire alarm system.

02. Is the TXC7301 an addressable sounder strobe?

No. The TXC7301 is a conventional, non-coding device and does not use an addressable loop address.

03. Does the TXC7301 provide both audible and visual alarm signals?

Yes. The supplied manual describes combined acoustic and optical alarm operation using a sounder and multiple LEDs.

04. What power supply does the TXC7301 require?

It is designed for a nominal 24 VDC supply and has a specified operating range of 15 to 28 VDC.

05. Is the TXC7301 polarity sensitive?

The supplied V1.0 installation manual identifies positive and negative 24 VDC terminals, so polarity should be observed for this documented version. Some current online product information describes the unit as non-polarized, so confirm the exact production version before wiring.

06. What is the starting current of the TXC7301?

The manual specifies a power-supply starting current below 10.0 mA. It does not identify this value as the standby or continuous alarm current, so those figures should be confirmed separately when calculating circuit capacity.

07. How loud is the TXC7301 sounder?

The specified sound pressure level is 75 to 105 dB at a distance of 3 meters. Actual sound distribution depends on the installation environment and mounting position.

08. Does the TXC7301 sound reach full output immediately?

No. According to the manual, the sound rises from low to high over approximately 3 to 5 seconds after activation.

09. What is the flash frequency of the TXC7301 strobe?

The specified LED flash frequency is 1.0 to 1.8 Hz.

10. Can the sounder and strobe be controlled independently?

The supplied manual describes combined acoustic and optical alarm operation but does not confirm independent sounder-only or strobe-only control. Any requirement for separate control should be verified before ordering.

11. Does the TXC7301 offer selectable alarm tones?

Selectable or programmable tones are not documented in the supplied V1.0 manual. Confirm any project-specific tone requirement before ordering.

12. What are the dimensions and weight of the TXC7301?

With its base, the unit is approximately 100 mm in diameter and 44 mm high, with a stated weight of about 108 g.

13. What operating environment is specified for the TXC7301?

The supplied V1.0 manual specifies -10°C to +50°C and up to 95% relative humidity without condensation. Some current online product information lists +55°C as the upper limit, so use the supplied manual value for this version and confirm the exact production specification when necessary.

14. Can the TXC7301 be installed outdoors?

The supplied manual does not state an IP rating or confirm outdoor use. The installation environment and any required weather protection should therefore be verified against the approved system design and local requirements.

15. How is the TXC7301 connected?

The supplied V1.0 manual shows a 24 VDC connection with terminals 1 and 4 marked positive and terminals 2 and 3 marked negative. Installation should be completed by qualified personnel in accordance with the approved wiring design and local requirements.

16. Is the TXC7301 compatible with every conventional fire alarm control panel?

Compatibility should not be assumed from the 24 VDC rating alone. Confirm the panel or notification-circuit voltage, available current, polarity arrangement, supervision method, and applicable approval requirements before specifying the TXC7301.

17. What certifications does the TXC7301 have?

The supplied V1.0 manual does not identify a product certification or confirm compliance with a specific sounder or visual-alarm-device standard. Request the applicable certificate for the exact product version and destination market when certification is required.

18. How often should the TXC7301 be tested and maintained?

The manufacturer recommends regular functional testing and suggests an interval of about six months. This is product guidance only; the actual inspection, testing, and maintenance schedule must follow local regulations, the approved system design, site conditions, and the approved maintenance plan.