Fire Emergency Evacuation Broadcast Panel

The DHI-HY-1801 Fire Emergency Evacuation Broadcast Panel comprises an area control panel, audio source equipment, and a broadcast power amplifier, forming a Fire Emergency Evacuation Broadcast Panel System that includes a fire alarm panel, output modules, a radio speaker, and other components.

Brand:
Dahua
SKU:
DHI-HY-1801
DHI-HY-1801 · Product Overview

Fire Emergency Evacuation Broadcast Panel

The DHI-HY-1801 combines broadcast operation, emergency audio source management and a power amplifier in a fire emergency broadcasting system. Operators can use the front-panel LCD, keypad and handheld microphone to manage recorded announcements, live voice broadcasts and external audio sources.

  • Dedicated EMER key for emergency broadcasting and a handheld microphone for live announcements.
  • LCD and status indicators for operation, power and fault information.
  • Fixed-voltage 120 VAC speaker output with 350 W rated output power.
350 WRated output power
120 VACSpeaker output
30 minRecording duration
DHI-HY-1801
Actual Front Panel

What Each Front-Panel Control Does

The numbered illustration identifies five operating areas on the DHI-HY-1801. Match each number with the detailed operating notes below.

DHI-HY-1801 front panel with five numbered callouts for microphone, status indicators, LCD screen, keypad and input ports
Five numbered front-panel controls correspond to the descriptions below.
1

Handheld Microphone

The left-mounted microphone is for live voice broadcasts. Press and hold its talk button to speak; release the button to end microphone broadcasting. During an emergency broadcast, microphone speech can be recorded automatically.

2

Status Indicator LEDs

The panel visibly identifies Power On, Main Power, Backup Power, Fault, Automatic, Emergency and Silence. The Fault indicator and audible warning signal help operators identify abnormal conditions.

3

LCD Information Screen

Shows the standby interface and operation menus. If a fault persists, the screen can automatically display the corresponding fault information.

4

Keypad and Dedicated Controls

Includes labeled All On, EMER and Silence keys, navigation/confirmation keys, and context-dependent playback or menu controls. The EMER key opens or exits emergency radio; Silence mutes the audible fault warning.

5

MIC, AUX and USB Ports

MIC connects the handheld microphone; AUX accepts a 3.5 mm external audio cable; USB accepts a compatible USB 2.0 flash drive for supported MP3 playback or audio import operations.

Important: The microphone is a one-way live broadcast input; the supplied materials do not establish a two-way intercom feature. Key actions can vary by the current menu or operating mode.
Broadcast Operation

Four Audio and Broadcast Modes

The panel supports emergency pre-recorded messages, operator voice announcements, USB audio and external AUX playback. These are different audio paths, not four independently addressed speaker zones.

01 · Emergency

EMER Radio

Press EMER or select emergency radio from the menu to play a configured emergency audio source. Record1 is the default source; Record2 can be selected and falls back to Record1 when empty.

02 · Live voice

MIC Radio

Press and hold the handheld microphone button and speak. Releasing the button stops microphone broadcast. Voice can be recorded automatically when used during emergency radio.

03 · Local media

USB / MP3

Insert a compatible USB flash drive, then select MP3 in the menu. Use the keypad for track selection, play/pause and playback-level controls.

04 · External source

AUX Input

Connect an external audio device through the 3.5 mm AUX input and select AUX from the menu to broadcast the incoming signal.

Emergency source editing supports microphone recording or USB import. The manual specifies a maximum emergency audio-source clip length of 30 seconds; this is separate from the 30-minute total recording capacity.
Control, Protection and Fault Reporting

Built for Supervised Emergency Broadcasting

Main & Backup Power Monitoring

Supervises the main power supply and standby power supply and reports detected faults through sound and light indications.

Speaker-Line Fault Detection

Monitors the constant-voltage broadcast output line for faults, helping the operator identify broadcast circuit abnormalities.

Overload Protection

Reduces output voltage during minor overloads and shuts off output in severe overload conditions.

Programmable Air Cooling

Intelligent, programmable fan cooling helps manage amplifier temperature during operation.

LCD Fault Information

The screen provides operating menus and fault information, complementing the visible indicators and audible warning.

Fire Alarm Linkage

Supports external control-system integration via a 24 V start signal. A protocol-conversion communication module is described in the manual; verify the specific implementation for each project.

System Components & Expansion

A Broadcast Panel with Three Matching Speaker Models

The DHI-HY-1801 is the central broadcast panel. Together with the fire alarm control panel, linkage/output equipment and field speakers, it can form a fire emergency evacuation broadcast system. DHI-HY-1820, DHI-HY-1821 and DHI-HY-1822 are alternative speaker types for different mounting conditions, not three controller-expansion boards.

Fire Alarm / LinkageExternal 24 V start signal / project interfaces
DHI-HY-1801Audio source selection · amplifier · control
Speaker Output Circuits120 VAC constant-voltage system; output modules as specified
Field LoudspeakersDHI-HY-1820 / 1821 / 1822
DHI-HY-1820 surface-mounted ceiling speaker
DHI-HY-1820

Surface-mounted ceiling speaker

3 W · AC 120 V
DHI-HY-1821 ceiling-mounted speaker
DHI-HY-1821

Ceiling-mounted speaker

3 W · AC 120 V
DHI-HY-1822 wall-mounted speaker
DHI-HY-1822

Wall-mounted speaker

3 W · AC 120 V
Speaker quantity and wiring topology are project-specific. Do not infer the number of supported speakers or independently controlled zones from the 350 W amplifier rating alone. Check the manufacturer output-module scheme and system design requirements.
Verified Technical Data

DHI-HY-1801 Specifications

ModelDHI-HY-1801
Product TypeFire Emergency Evacuation Broadcast Panel
Main Power SupplyAC 220 V / 50 Hz (datasheet rating)
Speaker Output120 VAC constant-voltage output
Rated Output Current / Power2.92 A / 350 W
Recording Duration30 minutes total; circular recording retains the latest 30 minutes when full
Emergency Audio ClipUp to 30 seconds for a configured emergency broadcast audio source (manual)
Signal-to-Noise Ratio≥ 70 dB
Dimensions318 × 245 × 127 mm
Operating Conditions0°C to +40°C; ≤ 95% RH (non-condensing)
InstallationStanding Cabinet / Wall-Mounted — verify mounting arrangement for the supplied version
Installation reference: The user's manual specifies a twisted-pair fixed-voltage output line with conductor cross-section ≥ 1.5 mm², insulation resistance to ground > 20 MΩ and avoidance of short circuits and interference sources. The manual also identifies separate main/backup AC power connections and an external 24 V emergency start signal. Installation and connection must follow the confirmed model wiring diagram and local requirements.

Need the Correct Speaker and Broadcast Configuration?

Share the building type, speaker locations, proposed audio circuits and required fire alarm interfaces for a project-specific quotation.

Request a System Quote
Type Model Description
Fire Emergency Evacuation Broadcast Panel DHI-HY-1801 Fire Emergency Evacuation Broadcast Panel
Ceiling-mounted Speaker DHI-HY-1820 Surface-mounted Ceiling Speaker
Ceiling-mounted Speaker DHI-HY-1821 Ceiling-mounted Speaker
Wall-mounted Speaker DHI-HY-1822 Wall-mounted Speaker

Technical Specification

DHI-HY-1801
Main Power Supply AC220V/50Hz
Output Voltage Fixed voltage output: 120 VAC
Rated Output Current and Power 2.92A / 350W
Recording Duration 30 min
Signal-to-noise Ratio ≥ 70 dB
Dimensions 318 mm × 245 mm × 127 mm
Operating Temperature 0°C to +40°C
Operating Humidity ≤ 95% RH (no condensation)
Installation Standing cabinet
DHI-HY-1820
Rated Power 3 W
Rated Voltage AC 120V
Sensitivity 83±2 dB (1m, 1W)
Color White
Dimensions Φ194 mm × H60 mm
Operating Temperature 0°C to +40°C
Operating Humidity ≤ 95% RH (no condensation)
Installation Surface-mounted
DHI-HY-1821
Rated Power 3 W
Rated Voltage AC 120V
Sensitivity 83±2 dB (1m, 1W)
Color White
Dimensions Φ184 mm × H61.1 mm
Operating Temperature 0°C to +40°C
Operating Humidity ≤ 95% RH (no condensation)
Installation Ceiling-mounted
DHI-HY-1822
Rated Power 3 W
Rated Voltage AC 120V
Sensitivity 83±2 dB (1m, 1W)
Color White
Dimensions Φ184 mm × H61.1 mm
Operating Temperature 0°C to +40°C
Operating Humidity ≤ 95% RH (no condensation)
Installation Wall-mounted

 

Free Preliminary System Drawings

Working on a project budget without a system layout? FireMarket provides free preliminary drawings to help you estimate equipment quantities and costs.

Request Free Preliminary Drawings

Related Products