Base Mount Short Circuit Isolator

The TX7232 base-mount short-circuit isolator is compatible with the TX7004/TX7002 Analogue Intelligent Fire Alarm Control Panel, produced by the same manufacturer, T&A, to avoid addressable communication compatibility issues.

Brand:
Tanda UK
SKU:
TX7232
Capacity:
70 Devices
Certification:
CE, CPR, LPCB

TX7232 Base Mount Short Circuit Isolator

The TX7232 is a mounting base with built-in short-circuit isolation for T&A addressable fire alarm systems. The TX7100, TX7110, and TX7120 detectors mount directly on the base.

Use the base and a compatible detector with the TX7004 addressable control panel.

EN 54-17:2005 Direct detector mounting Up to 70 monitored devices
TX7232 Base Mount Short Circuit Isolator

Compatible Detectors

Select a detector and play the animation to see how it mounts on the TX7232 base.

TX7100 detector above the TX7232 base.

TX7100 detector
TX7232 base
Conceptual assembly shown with individual product photos.

TX7110

Addressable heat detector

TX7120

Multisensor smoke and heat detector

Communication with the TX7004

Conceptual signal-flow illustration. Refer to the installation manual for system wiring.

Detector B is offline. Detectors A and C continue communicating with the TX7004.

Key Specifications

Loop voltage
24 V DC nominal (16–28 V DC)
Current draw
0.15 mA standby · 2 mA active
LED indication
Single blink in normal operation · steady on when active
Dimensions
Ø100.7 × 34 mm
Ingress protection
IP30
Operating temperature
−10°C to +50°C

The installation manual identifies LPCB certification, EN 54-17:2005 compliance, and CPR certificate 2831-CPR-F4776.

Listed LPCB / CE-CPR
Compliance EN54-17:2005
Power Rating  
Input Voltage 24VDC [16V to 28V]
Current Consumption Standby 0.15mA, Alarm: 1.8Ma
Maximum Open Voltage(VSO MAX) 11V
Minimum Open Voltage(VSO MIN) 8V
Maximum Close Voltage(VSC MAX) 3V
Minimum Close Voltage(VSC MIN) 1.4V
Maximum Continuous Current (IC MAX) 500mA
Maximum Transient Output Current (IS MAX) 5A
Maximum Leakage Current (IL MAX) 2mA
Max closed impedance (ZC MAX) 0.65 ohms
Module  
Protocol T&A
Number of monitored Max 70 Devices
Output Impedance 480 ohms
Indicator Status Normal: Single blink/Active: Steady-on
Material / Color ABS / White Glossy finishing
Dimension / Height Diameter:100.7 / 35mm
Weight 55g (with Base)
Ingress Protection IP30
Humidity 0 to 95% Relative Humidity, Non condensing

PRODUCT & TECHNICAL SUPPORT

Base Mount Short Circuit Isolator FAQs

Frequently asked questions about this product, configuration, compatibility and technical requirements.

01. What is the TX7232 Base Mount Short Circuit Isolator used for?

The TX7232 is a loop-powered isolator that protects an addressable fire alarm loop by disconnecting a short-circuited section while allowing devices on unaffected sections to continue operating.

02. What is the main advantage of the TX7232 base-mount design?

The TX7232 combines short-circuit isolation with a compact base-mount format, and a compatible detector can be mounted directly above the isolator. Confirm detector compatibility for the selected system configuration before ordering.

03. What happens when the TX7232 detects a short circuit?

TX7232 isolators on either side of the fault open the circuit and isolate the affected section, helping limit the impact of the wiring fault on the rest of the loop.

04. Does the TX7232 automatically restore the isolated section?

Yes. The TX7232 continues monitoring the fault and automatically reinstates the isolated section after the short circuit has been cleared.

05. How many devices can the TX7232 monitor?

The TX7232 is specified to monitor up to 70 devices. The final device quantity and isolator placement must follow the approved loop design and applicable local requirements.

06. Which fire alarm control panel is confirmed as compatible with the TX7232?

The TX7232 is confirmed for use with the TX7004 Analogue Intelligent Fire Alarm Control Panel using the TANDA protocol. Compatibility with other panels or brands must be confirmed before ordering.

07. Is the TX7232 compliant with EN 54-17?

The TX7232 is identified as compliant with EN 54-17:2005, with LPCB reference 1330f/02 and CPR reference 2831-CPR-F4776. Current certificate status and project-market acceptance should be confirmed before ordering.

08. Does the TX7232 require a separate power supply?

No. The TX7232 is powered directly from the detection loop, so it does not require a separate local power supply.

09. What is the operating voltage of the TX7232?

The TX7232 has a nominal operating voltage of 24 VDC and a specified operating range from 16 VDC to 28 VDC.

10. What is the current consumption of the TX7232?

The specified current consumption is 0.15 mA in standby and 2 mA when active.

11. What current limits apply to the TX7232?

The TX7232 has a maximum continuous current of 500 mA, a maximum transient output current of 5 A, and a maximum leakage current of 2 mA.

12. What do the TX7232 LED indications mean?

A single blinking indication represents normal operation, while a steady-on indication shows that the isolator is active.

13. What are the dimensions and weight of the TX7232?

The TX7232 has a diameter of 100.7 mm and a specified thickness of 34 mm. It weighs approximately 108 g with the cover and 91 g without the cover.

14. What environmental conditions are specified for the TX7232?

The TX7232 is specified for operation from -10°C to +50°C and at 0% to 95% relative humidity without condensation. Its enclosure rating is IP30.

15. How is the TX7232 installed?

The TX7232 can be secured to a wall through its mounting holes, with loop wiring routed through the cable entry. Installation and commissioning must be performed by qualified or factory-trained personnel in accordance with the approved design and applicable local requirements.

16. How are the TX7232 wiring terminals identified?

ZI+ and ZI- are the positive and negative bus-input terminals, while ZO+ and ZO- are the positive and negative bus-output terminals. L+ and L- are provided for the remote light connection.

17. How often should the TX7232 be maintained?

Semi-annual maintenance is manufacturer guidance for the TX7232 and may need adjustment for site conditions. The actual inspection, testing, and maintenance schedule must follow applicable local regulations, the approved system design, site conditions, and the approved maintenance plan.

18. How should the TX7232 be cleaned and serviced?

Clean the external surface with a damp cloth and do not attempt to repair the internal circuitry. Removal, testing, and replacement should be performed by qualified personnel, followed by verification of normal system operation.

19. What should be checked if the control panel reports a loop fault involving the TX7232?

Qualified personnel should check for incorrect wiring or a damaged electronic circuit. If the TX7232 is confirmed to be defective, it should be replaced rather than repaired at circuit level.