Addressable Zone Monitor and Sounder Circuit Module

The TX7222 Addressable Interface Module integrates conventional fire detectors, manual call points, and sounder/strobe circuits into an intelligent addressable fire alarm system. It monitors the conventional detection zone and reports alarm signals to the fire alarm control panel, which displays the module address to help identify the affected zone. It also activates compatible conventional sounders and strobes on command, supporting a coordinated system response. Compatible with the TANDA TX7004 Intelligent Addressable Fire Alarm Control Panel, the TX7222 provides addressable communication between the panel and conventional circuits. Its compact, plug-in design simplifies installation and maintenance.

Brand:
Tanda UK
SKU:
TX7222
Certification:
CE, DOE, TUV
Capacity:
32 Detectors & 10 Sounders

TX7222 Addressable Zone Monitor and Sounder Circuit Module

Connect conventional detection and notification circuits to a compatible TANDA addressable fire alarm system. The TX7222 reports conventional zone alarms to the panel and switches its conventional sounder circuit when commanded.

Conventional zone
Up to 32 conventional detectors on N/P
Address allocation
Two consecutive addresses
TANDA TX7222 addressable zone monitor and sounder circuit module

See the Signal Travel Through the Module

Choose a scenario to see which way the signal travels between a TX7004 control panel, the TX7222 and the conventional circuit.

Ready to demonstrate

A conventional zone alarm is reported via the TX7222 to the addressable panel.

Silent functional demonstration. Refer to the installation manual for terminal connections and circuit requirements.

Conventional Circuits on an Addressable Loop

Zone Monitoring

The N/P input monitors compatible conventional smoke or heat detectors and manual call points. The panel identifies the reporting module address.

Sounder Circuit

The S+/S− output serves compatible conventional sounder strobes. The manual shows this circuit with an end-of-line resistor and an external DC supply connected to the module.

Circuit Supervision

Enable Input Check with an end-of-line resistor to report open- and short-circuit faults. Output Check monitors the output voltage when enabled.

Two Consecutive Addresses

Reserve two consecutive addresses for each module. Use the TX7932 handheld programmer to configure addressing and circuit-check settings.

Plug-In Mounting

The module clips onto its terminal base, which mounts to a standard single-gang electrical back box.

Dedicated Beam Interface

The D+/D− 24 V DC control output is specified for the TX7130 beam detector. Use the TX7222 manual for the interface arrangement.

Specification Highlights

Addressable loop supply
16–28 V DC, 24 V DC nominal
External supply
20–28 V DC
End-of-line resistor
5.1 kΩ / ¼ W
Addressing
TANDA · range 1–254
Indicators
Alarm, fault and activation
Dimensions (L × W × H)
108 × 86 × 38 mm
Enclosure
IP30
Operating temperature
−10 °C to +50 °C
Weight with / without base
162 g / 87 g

PRODUCT & TECHNICAL SUPPORT

Addressable Zone Monitor and Sounder Circuit Module FAQs

Frequently asked questions about this product, configuration, compatibility and technical requirements.

01. What is the TX7222 Addressable Zone Monitor and Sounder Circuit Module used for?

The TX7222 is an addressable interface module that connects compatible conventional detectors or manual call points to an addressable fire alarm system and also provides a supervised circuit for compatible conventional sounder-strobe devices.

02. Why use the TX7222 instead of a basic addressable input module?

The TX7222 combines conventional zone monitoring and sounder-circuit control in one addressable module, allowing the panel to receive zone alarm or fault information and control a separate conventional notification circuit.

03. Which conventional initiating devices can be connected to the TX7222?

The TX7222 is specified for compatible conventional optical smoke detectors, rate-of-rise and fixed-temperature heat detectors, and conventional manual call points. Device compatibility and electrical loading must be confirmed before installation.

04. How many conventional detectors can the TX7222 monitor?

The N and P zone terminals are specified for parallel connection of up to 32 compatible conventional detectors. The final quantity must follow the detector compatibility data, external-power capacity, wiring calculation, approved system design, and applicable local requirements.

05. Can the TX7222 control conventional sounder-strobe devices?

Yes. The S+ and S- terminals are identified as the conventional sounder-strobe output. The permitted device type, quantity, polarity, and total current load must be confirmed for the selected notification devices and power supply.

06. Does the TX7222 monitor conventional zone wiring faults?

Yes. With the specified end-of-line supervision and Input Check mode enabled, the TX7222 can report open- or short-circuit wiring faults to the fire alarm control panel.

07. Can the TX7222 detect removal of a conventional detector?

The monitored conventional zone is designed to report detector removal as a fault when the compatible detector base and end-of-line arrangement support the required circuit supervision.

08. Does the TX7222 supervise the sounder output circuit?

Yes. Output Check mode enables voltage monitoring so the module can report a low-voltage output condition associated with a wiring fault. Commissioning personnel must configure and test the supervision for the installed circuit.

09. What end-of-line resistor is specified for the TX7222?

The TX7222 specifies a 5.1 kΩ, 1/4 W end-of-line resistor for supervised circuits. The resistor must be installed in the correct end-of-line position according to the approved wiring design.

10. How many addressable-loop addresses does the TX7222 use?

The TX7222 uses two consecutive addresses. The address plan must reserve both values and prevent either address from duplicating another loop device.

11. What address range does the TX7222 support?

The TX7222 uses the TANDA protocol and supports address values from 1 to 254. Because it occupies two consecutive addresses, the selected starting address must leave the next address available.

12. Which fire alarm control panel is confirmed as compatible with the TX7222?

The TX7222 is confirmed for use with the TX7004 Analogue Intelligent Fire Alarm Control Panel using the TANDA protocol. Compatibility with other control panels or brands must be confirmed before ordering.

13. What programming tool is required for the TX7222?

The TX7932 handheld programmer is specified for setting the two addresses and configuring the input and output monitoring parameters. The programmer is purchased separately and should be used by qualified commissioning personnel.

14. What power supplies does the TX7222 require?

The addressable-loop input is nominally 24 VDC with a specified range from 16 VDC to 28 VDC, and the external power-supply input accepts 20 VDC to 28 VDC. The external supply and wiring must be sized for the connected zone and output loads.

15. What is the current consumption of the TX7222?

The specified loop current is 1.5 mA in standby and 6 mA in alarm. The external supply current is specified as 15 mA in standby and up to 500 mA in alarm.

16. Can the TX7222 provide a 24 VDC control output for the TX7130 beam detector?

The D+ and D- terminals provide a 24 VDC control output specifically for the normally open interface of the TX7130. This output must not be short-circuited or used for an unverified load.

17. What do the TX7222 LED indicators show?

The red alarm LED blinks once during normal operation and remains steady in alarm, the yellow fault LED remains off normally and steady during a fault, and the red activation LED remains off normally and steady when the output is active.

18. What are the dimensions and weight of the TX7222?

The TX7222 measures 108 × 86 × 38 mm. It weighs approximately 162 g with the base and 87 g without the base.

19. What environmental conditions are specified for the TX7222?

The TX7222 is specified for operation from -10°C to +50°C and at 0% to 95% relative humidity without condensation. Its enclosure rating is IP30.

20. How is the TX7222 mounted?

The fixed base can be mounted on a standard one-gang electrical back box using two M4 screws, after which the module aligns with the base and locks into place. Installation must be performed by qualified personnel.

21. How often should the TX7222 be maintained and tested?

Semi-annual maintenance and testing are manufacturer guidance and may need adjustment for site conditions. Actual implementation must follow applicable local regulations, the approved system design, site conditions, and the approved maintenance plan.

22. What should be checked if the TX7222 address does not enroll?

Qualified personnel should check for loose wiring and duplicate addresses, verify that two consecutive addresses are available, correct the issue, and recommission the module.

23. Can the TX7222 electronic circuitry be repaired on site?

Internal circuit repair should not be attempted. If the electronic circuitry is confirmed to be damaged, the module should be replaced and normal system operation verified by qualified personnel.