TX7300 Addressable Fire Alarm Sounder Strobe
Configure audible and supplementary visual warning on a compatible TANDA addressable fire alarm system. Choose combined, sounder-only or strobe-only operation to suit the alarm sequence.
- Sound patterns
- 17 tones
- Visual indicator
- 10 LEDs
- Application
- Type A indoor
Explore the Three Warning Modes
Choose a mode and watch how a TX7004 control panel command activates the TX7300.
The control panel activates the programmed warning output.
Silent illustration. Sound and flash timing are shown for demonstration.
Configure the Alarm Sequence
Single Address
Assign one address for the evacuation stage.
Dual Address
Use two consecutive addresses for the alert and evacuation stages. Configure the sequence at the panel.
Wall or Ceiling Mount
The TX7300 twists onto its mounting base. The manual specifies a standard single-gang electrical back box.
Power Options
Use loop power in Saving Mode or an external supply in Typical Mode, as described in the installation manual.
On-Site Programming
Set address, output type and sound pattern with the TX7930 handheld programmer.
Specification and Approval Highlights
- Loop supply
- 18–27.5 V DC
- External supply
- 20–27.5 V DC
- TANDA device addresses
- 1–254
- Size with base
- Ø110 × 39.6 mm
- Operating temperature
- −10 °C to +50 °C
- Enclosure
- IP21
EN 54-3 Sounder Approval
The supplied LPCB and CPR certificates cover sounder tones 14, 16 and 17. LPCB reference 1330d/01 · CPR certificate 2831-CPR-F2793.
The certificates state that the strobe function is not approved to EN 54-23.