{"id":3998,"date":"2026-09-03T13:57:13","date_gmt":"2026-09-03T05:57:13","guid":{"rendered":"https:\/\/firemarket.com\/?p=3998"},"modified":"2026-09-22T16:03:19","modified_gmt":"2026-09-22T08:03:19","slug":"toxic-gas-detector-guide","status":"publish","type":"post","link":"https:\/\/firemarket.com\/hi\/blogs\/toxic-gas-detector-guide\/","title":{"rendered":"What Is a Toxic Gas Detector? Types, Working Principle and Selection Guide"},"content":{"rendered":"<style>\n\/* =========================\n   FireMarket Article Layout\n   ========================= *\/<\/p>\n<p>.fm-gas-guide{\n    max-width:920px;\n    margin:0 auto;\n    padding:10px 24px 60px;\n    color:#263238;\n    font-size:17px;\n    line-height:1.82;\n    font-family:inherit;\n    box-sizing:border-box;\n}<\/p>\n<p>.fm-gas-guide *{\n    box-sizing:border-box;\n}<\/p>\n<p>\/* ---------- Article Header ---------- *\/<\/p>\n<p>.fm-gas-guide .article-header{\n    margin:10px 0 34px;\n    padding-bottom:26px;\n    border-bottom:1px solid #e3eaf0;\n}<\/p>\n<p>.fm-gas-guide h1{\n    margin:0 0 20px;\n    color:#123d68;\n    font-size:2.45em;\n    line-height:1.18;\n    letter-spacing:-0.02em;\n    font-weight:700;\n}<\/p>\n<p>.fm-gas-guide .article-lead{\n    margin:0;\n    color:#44515c;\n    font-size:1.08em;\n    line-height:1.85;\n}<\/p>\n<p>.fm-gas-guide .article-lead + .article-lead{\n    margin-top:12px;\n}<\/p>\n<p>\/* ---------- Typography ---------- *\/<\/p>\n<p>.fm-gas-guide p{\n    margin:0 0 1.35em;\n    line-height:1.82;\n    text-indent:0;\n}<\/p>\n<p>.fm-gas-guide h2{\n    position:relative;\n    margin:2.6em 0 .85em;\n    padding-left:14px;\n    color:#123d68;\n    font-size:1.72em;\n    line-height:1.3;\n    font-weight:700;\n}<\/p>\n<p>.fm-gas-guide h2::before{\n    content:\"\";\n    position:absolute;\n    left:0;\n    top:.12em;\n    width:4px;\n    height:1.1em;\n    border-radius:3px;\n    background:#0b63a5;\n}<\/p>\n<p>.fm-gas-guide h3{\n    margin:1.8em 0 .65em;\n    color:#24577f;\n    font-size:1.24em;\n    line-height:1.4;\n    font-weight:700;\n}<\/p>\n<p>.fm-gas-guide strong{\n    color:#1d2d3a;\n}<\/p>\n<p>\/* ---------- Links ---------- *\/<\/p>\n<p>.fm-gas-guide a{\n    color:#0b63a5;\n    text-decoration:underline;\n    text-decoration-thickness:1px;\n    text-underline-offset:3px;\n}<\/p>\n<p>.fm-gas-guide a:hover{\n    text-decoration-thickness:2px;\n}<\/p>\n<p>\/* ---------- TOC ---------- *\/<\/p>\n<p>.fm-gas-guide .toc{\n    margin:30px 0 38px;\n    padding:22px 26px;\n    background:#f6f9fc;\n    border:1px solid #dce6ee;\n    border-radius:10px;\n}<\/p>\n<p>.fm-gas-guide .toc-title{\n    margin:0 0 12px;\n    color:#123d68;\n    font-size:1.1em;\n    font-weight:700;\n}<\/p>\n<p>.fm-gas-guide .toc ul{\n    margin:0;\n    padding-left:1.25em;\n}<\/p>\n<p>.fm-gas-guide .toc li{\n    margin:7px 0;\n    line-height:1.55;\n}<\/p>\n<p>\/* ---------- Lists ---------- *\/<\/p>\n<p>.fm-gas-guide ul,\n.fm-gas-guide ol{\n    margin:.45em 0 1.55em;\n    padding-left:1.6em;\n}<\/p>\n<p>.fm-gas-guide li{\n    margin:0 0 .65em;\n    padding-left:.15em;\n    line-height:1.72;\n}<\/p>\n<p>\/* ---------- Figures ---------- *\/<\/p>\n<p>.fm-gas-guide figure{\n    margin:2em auto 2.2em;\n    text-align:center;\n}<\/p>\n<p>.fm-gas-guide figure img{\n    display:block;\n    width:auto;\n    max-width:100%;\n    height:auto;\n    margin:0 auto;\n    border-radius:10px;\n    box-shadow:0 4px 18px rgba(24,52,74,.08);\n}<\/p>\n<p>\/* ---------- Table ---------- *\/<\/p>\n<p>.fm-gas-guide .table-wrap{\n    width:100%;\n    margin:1.5em 0 2em;\n    overflow-x:auto;\n    border:1px solid #d8e1e8;\n    border-radius:10px;\n}<\/p>\n<p>.fm-gas-guide table{\n    width:100%;\n    margin:0;\n    border-collapse:collapse;\n    font-size:.95em;\n    line-height:1.55;\n    background:#fff;\n}<\/p>\n<p>.fm-gas-guide th{\n    background:#123d68;\n    color:#fff;\n    text-align:left;\n    font-weight:600;\n}<\/p>\n<p>.fm-gas-guide th,\n.fm-gas-guide td{\n    padding:14px 16px;\n    border-right:1px solid #dbe3e9;\n    border-bottom:1px solid #dbe3e9;\n    vertical-align:top;\n}<\/p>\n<p>.fm-gas-guide th:last-child,\n.fm-gas-guide td:last-child{\n    border-right:0;\n}<\/p>\n<p>.fm-gas-guide tbody tr:last-child td{\n    border-bottom:0;\n}<\/p>\n<p>.fm-gas-guide tbody tr:nth-child(even){\n    background:#f6f9fb;\n}<\/p>\n<p>\/* ---------- Highlight \/ Note ---------- *\/<\/p>\n<p>.fm-gas-guide .note-box{\n    margin:1.7em 0;\n    padding:18px 20px;\n    background:#f5f9fc;\n    border-left:4px solid #0b63a5;\n    border-radius:6px;\n}<\/p>\n<p>.fm-gas-guide .note-box p:last-child{\n    margin-bottom:0;\n}<\/p>\n<p>\/* ---------- Product Cards ---------- *\/<\/p>\n<p>.fm-gas-guide .product-block{\n    margin:1.5em 0 2.4em;\n    padding:22px;\n    border:1px solid #dce5ec;\n    border-radius:10px;\n    background:#fff;\n}<\/p>\n<p>.fm-gas-guide .product-block h3{\n    margin-top:0;\n}<\/p>\n<p>\/* ---------- FAQ ---------- *\/<\/p>\n<p>.fm-gas-guide .faq-item{\n    margin:0 0 18px;\n    padding:20px 22px;\n    background:#f7f9fb;\n    border:1px solid #e1e7ec;\n    border-radius:9px;\n}<\/p>\n<p>.fm-gas-guide .faq-item h3{\n    margin:0 0 9px;\n    color:#123d68;\n}<\/p>\n<p>.fm-gas-guide .faq-item p{\n    margin:0;\n}<\/p>\n<p>\/* ---------- CTA ---------- *\/<\/p>\n<p>.fm-gas-guide .cta-box{\n    margin:2.5em 0 0;\n    padding:28px 30px;\n    background:#123d68;\n    color:#fff;\n    border-radius:12px;\n}<\/p>\n<p>.fm-gas-guide .cta-box h2{\n    margin:0 0 14px;\n    padding-left:0;\n    color:#fff;\n}<\/p>\n<p>.fm-gas-guide .cta-box h2::before{\n    display:none;\n}<\/p>\n<p>.fm-gas-guide .cta-box p{\n    color:#edf4f8;\n}<\/p>\n<p>.fm-gas-guide .cta-box p:last-child{\n    margin-bottom:0;\n}<\/p>\n<p>.fm-gas-guide .cta-box a{\n    color:#fff;\n    font-weight:700;\n    text-decoration:underline;\n}<\/p>\n<p>\/* ---------- Mobile ---------- *\/<\/p>\n<p>@media(max-width:680px){<\/p>\n<p>    .fm-gas-guide{\n        padding:8px 16px 42px;\n        font-size:16px;\n        line-height:1.78;\n    }<\/p>\n<p>    .fm-gas-guide h1{\n        font-size:2em;\n        line-height:1.22;\n    }<\/p>\n<p>    .fm-gas-guide h2{\n        margin-top:2.25em;\n        font-size:1.45em;\n    }<\/p>\n<p>    .fm-gas-guide h3{\n        font-size:1.18em;\n    }<\/p>\n<p>    .fm-gas-guide .toc{\n        padding:18px 20px;\n    }<\/p>\n<p>    .fm-gas-guide th,\n    .fm-gas-guide td{\n        min-width:150px;\n        padding:12px 13px;\n    }<\/p>\n<p>    .fm-gas-guide .product-block{\n        padding:18px;\n    }<\/p>\n<p>    .fm-gas-guide .cta-box{\n        padding:22px 20px;\n    }\n}\n<\/style>\n<article class=\"fm-gas-guide\">\n<p>    <!-- Article Header --><\/p>\n<header class=\"article-header\">\n<h1>What Is a Toxic Gas Detector? Types, Working Principle and Selection Guide<\/h1>\n<p class=\"article-lead\">\n            A <strong>toxic gas detector<\/strong> is a safety instrument designed to measure harmful gases in the air and warn people or a control system when concentration reaches a configured level. Unlike a smoke detector, it responds to a specific gas or gas family rather than visible combustion products.\n        <\/p>\n<p class=\"article-lead\">\n            Toxic gas detection is used in petrochemical plants, steel works, wastewater facilities, laboratories, battery rooms, cold storage, confined spaces, and other locations where a leak or process release could threaten workers. The correct detector depends on the target gas, expected concentration, environmental conditions, certification, and required alarm response.\n        <\/p>\n<\/header>\n<p>    <!-- Main Image --><\/p>\n<figure class=\"wp-block-image size-full\">\n        <img fetchpriority=\"high\"\n            src=\"https:\/\/firemarket.com\/wp-content\/uploads\/2026\/09\/toxic-gas-detector-system.webp\"\n            width=\"1200\"\n            height=\"630\"\n            loading=\"eager\"\n            decoding=\"async\"\n            alt=\"Fixed and portable toxic gas detectors monitoring an industrial facility\"\n        \/><br \/>\n    <\/figure>\n<p>    <!-- Table of Contents --><\/p>\n<nav class=\"toc\" aria-label=\"Table of contents\">\n<div class=\"toc-title\">In This Guide<\/div>\n<ul>\n<li><a href=\"#how-toxic-gas-detection-works\">How toxic gas detection works<\/a><\/li>\n<li><a href=\"#toxic-vs-combustible\">Toxic gas detector vs. combustible gas detector<\/a><\/li>\n<li><a href=\"#common-toxic-gases\">Common toxic gases<\/a><\/li>\n<li><a href=\"#fixed-vs-portable\">Fixed vs. portable toxic gas detectors<\/a><\/li>\n<li><a href=\"#sensor-technologies\">Sensor technologies<\/a><\/li>\n<li><a href=\"#select-gas-detection-system\">How to select a toxic gas detection system<\/a><\/li>\n<li><a href=\"#detector-placement\">Detector placement<\/a><\/li>\n<li><a href=\"#firemarket-products\">FireMarket product examples<\/a><\/li>\n<li><a href=\"#faq\">Frequently asked questions<\/a><\/li>\n<\/ul>\n<\/nav>\n<section id=\"how-toxic-gas-detection-works\">\n<h2>How Does Toxic Gas Detection Work?<\/h2>\n<p>\n            Air reaches the sensor by diffusion or through a pump. The sensor converts the presence of the target gas into an electrical signal, and the instrument calculates a concentration\u2014commonly shown in parts per million (ppm) or percent by volume.\n        <\/p>\n<p>\n            When the measured value crosses a programmed threshold, the detector may activate audible, visual, and vibration alarms. A fixed detector can also transmit its reading to a gas alarm panel, PLC, DCS, ventilation system, or emergency shutdown circuit.\n        <\/p>\n<div class=\"note-box\">\n<p>\n                The complete protection system therefore includes more than the sensing head: power, signal transmission, alarm logic, output devices, calibration, testing, and emergency procedures all matter.\n            <\/p>\n<\/p><\/div>\n<\/section>\n<section id=\"toxic-vs-combustible\">\n<h2>Toxic Gas Detector vs. Combustible Gas Detector<\/h2>\n<div class=\"table-wrap\">\n<table>\n<thead>\n<tr>\n<th>Item<\/th>\n<th>Toxic Gas Detector<\/th>\n<th>Combustible Gas Detector<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Main purpose<\/td>\n<td>Reduce exposure to poisonous gases<\/td>\n<td>Warn before a flammable atmosphere approaches ignition risk<\/td>\n<\/tr>\n<tr>\n<td>Typical unit<\/td>\n<td>ppm or % volume<\/td>\n<td>%LEL<\/td>\n<\/tr>\n<tr>\n<td>Common gases<\/td>\n<td>CO, H2S, NH3, Cl2, SO2, NO2<\/td>\n<td>Methane, propane, hydrogen and solvents<\/td>\n<\/tr>\n<tr>\n<td>Common sensor<\/td>\n<td>Electrochemical, PID or infrared depending on gas<\/td>\n<td>Catalytic bead, infrared or semiconductor<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<p>\n            Some multi-gas instruments monitor toxic gas, oxygen, and combustible gas simultaneously. However, one sensor cannot be assumed to detect every hazard. The specified gas list, measuring range, cross-sensitivity, response time, and certification must be checked for each configuration.\n        <\/p>\n<\/section>\n<section id=\"common-toxic-gases\">\n<h2>Common Toxic Gases<\/h2>\n<ul>\n<li>\n                <strong>Carbon monoxide (CO):<\/strong><br \/>\n                produced by incomplete combustion; colorless and difficult to recognize without an instrument.\n            <\/li>\n<li>\n                <strong>Hydrogen sulfide (H2S):<\/strong><br \/>\n                associated with oil and gas, wastewater, sewers, and some industrial processes.\n            <\/li>\n<li>\n                <strong>Ammonia (NH3):<\/strong><br \/>\n                used in refrigeration, fertilizer, chemical processing, and food facilities.\n            <\/li>\n<li>\n                <strong>Chlorine (Cl2):<\/strong><br \/>\n                used in water treatment and chemical production.\n            <\/li>\n<li>\n                <strong>Sulfur dioxide (SO2) and nitrogen dioxide (NO2):<\/strong><br \/>\n                may occur in combustion, processing, and industrial emissions.\n            <\/li>\n<li>\n                <strong>Volatile organic compounds (VOCs):<\/strong><br \/>\n                a broad group often measured with photoionization detection; the response depends on the compound and lamp energy.\n            <\/li>\n<\/ul>\n<div class=\"note-box\">\n<p>\n                <strong>Selection note:<\/strong> Do not select a detector from the gas name alone. Expected background, alarm setpoints, maximum release concentration, oxygen level, temperature, humidity, pressure, and interfering gases can all affect the choice.\n            <\/p>\n<\/p><\/div>\n<\/section>\n<section id=\"fixed-vs-portable\">\n<h2>Fixed vs. Portable Toxic Gas Detectors<\/h2>\n<h3>Fixed Detectors<\/h3>\n<p>\n            A fixed detector provides continuous monitoring at a defined location. It is normally installed near credible release points or where gas may accumulate, then connected to a controller or plant system. Fixed equipment suits permanent risks, automated ventilation, remote indication, and shutdown logic.\n        <\/p>\n<h3>Portable Detectors<\/h3>\n<p>\n            A portable detector travels with the worker. It supports personal exposure monitoring, pre-entry testing, leak checks, and confined-space work. Depending on the model, alarms may include sound, light, vibration, TWA, STEL, low, and high thresholds.\n        <\/p>\n<p>\n            The two formats are complementary. A fixed system monitors selected areas continuously, while a portable device follows the person and can test locations outside the fixed network.\n        <\/p>\n<\/section>\n<section id=\"sensor-technologies\">\n<h2>Sensor Technologies<\/h2>\n<h3>Electrochemical Sensors<\/h3>\n<p>\n            <strong>Electrochemical sensors<\/strong> are widely used for gases such as CO, H2S, NH3, Cl2, SO2, and NO2. They are compact and sensitive at ppm levels, but service life, temperature limits, humidity, and cross-sensitivity vary.\n        <\/p>\n<h3>Photoionization Detectors (PID)<\/h3>\n<p>\n            <strong>Photoionization detectors (PID)<\/strong> respond to many VOCs. They are useful for broad screening, but readings require the correct response factor and do not automatically identify an unknown compound.\n        <\/p>\n<h3>Infrared Sensors<\/h3>\n<p>\n            <strong>Infrared sensors<\/strong> can measure selected gases by light absorption. They may provide good stability for suitable targets, but the optical wavelength and gas characteristics must match.\n        <\/p>\n<h3>Catalytic Combustion Sensors<\/h3>\n<p>\n            <strong>Catalytic combustion sensors<\/strong> are primarily used for combustible gases in %LEL. They require oxygen and can be affected by poisoning or high gas exposure, so they should not be confused with a general toxic-gas sensor.\n        <\/p>\n<\/section>\n<section id=\"select-gas-detection-system\">\n<h2>How to Select a Toxic Gas Detection System<\/h2>\n<p>\n            Start with a documented hazard assessment, then confirm:\n        <\/p>\n<ol>\n<li>Target gas or gas mixture and the reason for monitoring it.<\/li>\n<li>Required measuring range, resolution, low\/high alarms, TWA, and STEL.<\/li>\n<li>Fixed, portable, diffusion, or pump-sampling format.<\/li>\n<li>Response time and acceptable transport delay.<\/li>\n<li>Temperature, humidity, dust, water, corrosive atmosphere, and cross-sensitivity.<\/li>\n<li>Hazardous-area approval, ingress protection, and local regulatory requirements.<\/li>\n<li>Output interface such as 4\u201320 mA, RS485, relays, HART, or a manufacturer bus.<\/li>\n<li>Calibration gas, bump-test method, sensor replacement, and maintenance access.<\/li>\n<\/ol>\n<p>\n            For industrial projects, compare the detector, controller, field wiring, alarm devices, and cause-and-effect logic as one system. FireMarket&#8217;s<br \/>\n            <a href=\"https:\/\/firemarket.com\/industrial-products\/\">industrial product portfolio<\/a><br \/>\n            can be used as a starting point when defining the required architecture.\n        <\/p>\n<\/section>\n<section id=\"detector-placement\">\n<h2>Detector Placement<\/h2>\n<p>\n            Place sensors from the release scenario\u2014not from gas density alone. Review leak sources, ventilation, air movement, process temperature, obstructions, occupied areas, and maintenance access.\n        <\/p>\n<p>\n            A lighter-than-air gas may rise, while a heavier gas may collect low, but heat, pressure, ventilation, and equipment geometry can change the actual path.\n        <\/p>\n<div class=\"note-box\">\n<p>\n                The final layout should be prepared or approved by a qualified designer and checked against applicable codes, standards, manufacturer instructions, and the site risk assessment.\n            <\/p>\n<\/p><\/div>\n<\/section>\n<section id=\"firemarket-products\">\n<h2>FireMarket Product Examples<\/h2>\n<div class=\"product-block\">\n<h3>ACTION AEC2232bX Fixed Gas Detector<\/h3>\n<figure class=\"wp-block-image size-full\">\n                <img loading=\"lazy\"\n                    src=\"https:\/\/firemarket.com\/wp-content\/uploads\/2026\/09\/action-aec2232bx-fixed-gas-detector.webp\"\n                    width=\"700\"\n                    height=\"443\"\n                    loading=\"lazy\"\n                    decoding=\"async\"\n                    alt=\"ACTION AEC2232bX fixed toxic and combustible gas detector\"\n                \/><br \/>\n            <\/figure>\n<p>\n                The<br \/>\n                <a href=\"https:\/\/firemarket.com\/flammable-and-toxic-gas-leakage-detector\/\">AEC2232bX series<\/a><br \/>\n                supports configurations for combustible, toxic, and hazardous gases. Published options include catalytic, semiconductor, electrochemical, infrared, and PID sensing; diffusion sampling; IP66 protection; field display; and several signal-output choices.\n            <\/p>\n<p>\n                The exact gas, range, material, certification, and interface must be selected for the project.\n            <\/p>\n<\/p><\/div>\n<div class=\"product-block\">\n<h3>ACTION BT-AEC2387 Portable Toxic Gas Detector<\/h3>\n<figure class=\"wp-block-image size-full\">\n                <img loading=\"lazy\"\n                    src=\"https:\/\/firemarket.com\/wp-content\/uploads\/2026\/09\/action-bt-aec2387-portable-toxic-gas-detector.webp\"\n                    width=\"520\"\n                    height=\"580\"\n                    loading=\"lazy\"\n                    decoding=\"async\"\n                    alt=\"ACTION BT-AEC2387 portable toxic gas detector\"\n                \/><br \/>\n            <\/figure>\n<p>\n                The BT-AEC2387 is a compact diffusion-type portable detector offered for gases including CO, H2S, NH3, and Cl2.\n            <\/p>\n<p>\n                The supplied catalog lists an IP66 enclosure, audible\/visual\/display\/vibration alarms, at least eight hours of continuous operation, and an Ex ib IIC T4 Gb explosion-protection marking.\n            <\/p>\n<p>\n                Available sensor and range combinations should be confirmed at quotation stage. FireMarket represents<br \/>\n                <a href=\"https:\/\/firemarket.com\/about-firemarket\/brands-represented-by-firemarket\/\">ACTION and other gas-detection brands<\/a>.\n            <\/p>\n<\/p><\/div>\n<\/section>\n<section id=\"faq\">\n<h2>Frequently Asked Questions<\/h2>\n<div class=\"faq-item\">\n<h3>Can One Toxic Gas Detector Detect Every Gas?<\/h3>\n<p>\n                No. Sensors are selected for particular gases or response groups. Multi-gas devices combine several sensors, but their configured gas list remains limited.\n            <\/p>\n<\/p><\/div>\n<div class=\"faq-item\">\n<h3>What Is the Difference Between a Bump Test and Calibration?<\/h3>\n<p>\n                A bump test exposes the detector to gas to confirm that the sensor and alarms respond. Calibration applies a known concentration to adjust or verify measurement accuracy according to the manufacturer&#8217;s procedure.\n            <\/p>\n<\/p><\/div>\n<div class=\"faq-item\">\n<h3>How Often Should a Detector Be Tested?<\/h3>\n<p>\n                Follow the manufacturer, site risk assessment, regulations, and company procedure. The interval depends on sensor technology, exposure, environment, criticality, and operating history.\n            <\/p>\n<\/p><\/div>\n<\/section>\n<section class=\"cta-box\">\n<h2>Plan Your Gas Detection Project<\/h2>\n<p>\n            Effective toxic gas detection begins with the hazard, not the device. Define the gas, concentration range, release points, environment, approvals, alarm strategy, and system interfaces before choosing a model.\n        <\/p>\n<p>\n            Need help comparing a fixed or portable solution?<br \/>\n            <a href=\"https:\/\/firemarket.com\/firemarket-contact\/\">Contact FireMarket<\/a><br \/>\n            with the target gas, measuring range, installation area, required certification, quantity, and controller interface.\n        <\/p>\n<\/section>\n<\/article>\n","protected":false},"excerpt":{"rendered":"<p>What Is a Toxic Gas Detector? Types, Working Principle and Selection Guide A toxic gas detector is a safety instrument designed to measure harmful gases in the air and warn people or a control system when concentration reaches a configured level. Unlike a smoke detector, it responds to a specific gas or gas family rather [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3999,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[143],"tags":[],"class_list":["post-3998","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs"],"acf":[],"_links":{"self":[{"href":"https:\/\/firemarket.com\/hi\/wp-json\/wp\/v2\/posts\/3998","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/firemarket.com\/hi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/firemarket.com\/hi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/firemarket.com\/hi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/firemarket.com\/hi\/wp-json\/wp\/v2\/comments?post=3998"}],"version-history":[{"count":4,"href":"https:\/\/firemarket.com\/hi\/wp-json\/wp\/v2\/posts\/3998\/revisions"}],"predecessor-version":[{"id":4151,"href":"https:\/\/firemarket.com\/hi\/wp-json\/wp\/v2\/posts\/3998\/revisions\/4151"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/firemarket.com\/hi\/wp-json\/wp\/v2\/media\/3999"}],"wp:attachment":[{"href":"https:\/\/firemarket.com\/hi\/wp-json\/wp\/v2\/media?parent=3998"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/firemarket.com\/hi\/wp-json\/wp\/v2\/categories?post=3998"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/firemarket.com\/hi\/wp-json\/wp\/v2\/tags?post=3998"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}