1-10 Loops 3-in-1 Fire Alarm Control Panel: FACP, FTS & FBS

The TX7008R is a modular, microprocessor-based analogue addressable fire alarm control panel designed for flexible system configuration and operation. Its rack-type enclosure can accommodate optional TANDA TG7 voice alarm and TN7 fire telephone systems, enabling integrated fire alarm, emergency communication, and broadcast functions within a single cabinet. System configuration and included equipment depend on project requirements.

Brand:
Tanda UK
SKU:
TX7008R
Loops:
Max. 10 / 2,540 Devices
Cabinet:
PA/VA + Telephone
Wiring:
Class A/B
Certification:
Complies with EN 54-2

Integrated Fire Safety

TX7008R Integrated Cabinet Configuration

The TX7008R is an intelligent analogue addressable fire alarm control panel. The pictured project configuration brings together fire alarm control, fire telephone equipment and fire broadcast equipment for centralized system operation.

01 / FIRE ALARM

Intelligent Fire Alarm Control

Analogue addressable detection, event monitoring and programmable control through the TX7008R.

02 / FIRE TELEPHONE

Emergency Communication

Dedicated telephone equipment shown in the integrated cabinet configuration.

03 / FIRE BROADCAST

Emergency Broadcast

Broadcast control equipment shown alongside the fire alarm and telephone sections.

TX7008R cabinet configuration showing fire alarm, telephone and broadcast sections

The graphic is an illustrative rendering; its physical details have not been verified against the supplied photograph. Cabinet integration and installed subsystems depend on the supplied project configuration. The TX7008R manual does not establish that the fire telephone and broadcast units are standard inclusions.

Panel Hardware

Clearly Organized Front-Panel Controls

Identify the main user-facing components from a front view of the cabinet, with dedicated display, operation and indication areas.

TX7008R front control panel with numbered component annotations

This graphic is a draft visual aid and its numbered annotations may not match the photographed components. Verify each hotspot against the actual equipment photo and the manual's front-panel diagram before publishing it as a technical reference.

Loop Expansion & Networking

Networkable at 1–8 Loops. Standalone at 9–10 Loops.

The TX7008R supports panel-to-panel communication when configured with 1 to 8 detection loops. If extended to 9 or 10 loops, it operates as a standalone control panel and cannot communicate with other fire alarm control panels.

TX7008R loop configurations: 1 to 8 loops allow panel networking; expansion to 9 to 10 loops disables communication with other control panels
Blue: networked 1–8-loop configuration. Red: standalone 9–10-loop configuration. Schematic diagram, not a wiring drawing.
1–8 LoopsNetwork Communication Supported

The panel can communicate with other compatible fire alarm control panels.

9–10 LoopsStandalone Operation Only

After expansion beyond eight loops, communication with other control panels is not supported.

254Addresses / Loop*
2,0328-Loop Ideal Capacity*
3,000Programmable Zones*

*Figures from TX7008R Installation & Operation Manual V1.0, Sections 1.2 and 1.4. The manual documents up to 8 loops. The optional 9–10-loop expansion and its restriction on panel-to-panel communication are based on the project configuration information supplied by FireMarket and require confirmation against the applicable upgraded model documentation. No unverified 9–10-loop total device capacity is claimed.

TX7008R commissioning feature graphic with control panel interface detail

Commissioning & Operation

Practical Tools for Configuration and Testing

A touchscreen interface and keypad provide alternative methods for operation and programming. The manual also lists several commissioning functions intended to assist installation and maintenance teams.

Auto Device EnrollmentRegister addressable devices connected to the detection loops.
Colour-Coded Loop MappingView loop mapping information during troubleshooting and commissioning.
Dual-Address Conflict & Device Mismatch MonitoringIdentify duplicate addresses and configuration inconsistencies.
One-Man TestingSupports zone testing with sounder On/Off options.
Manual V1.0 — Sections 1.2 / 4 / 5

Programmable Control

Cause & Effect for Coordinated Fire Response

The Command Builder function allows programmed input conditions to activate specified outputs or output groups. It supports project-specific cause-and-effect scenarios.

Detection and Alarm EventsFire alarm and other configured conditions can serve as control inputs.
Linked Output ControlCommissioners define which outputs or groups respond to selected events.
Building System InterlocksThe manual cites elevator control, air-handling shutdown, gas shutoff and damper control as examples of auxiliary commands.
Manual V1.0 — Sections 1.1 / 5.3.2.5
TX7008R example programmable cause and effect control graphic
Input Voltage 230VAC +10%-15%,50Hz Humidity 0 to 95% Relative Humidity, Non condensing
Network Panel to panel 512 Panels- Single Ring[Ideal] Temperature -5℃~+40℃
Communication Card CanBus Dimension/HWD 1715 x 550 x 480mm
Protocol/Addressing T&A, Value range from 1 to 254 Material/Color Flat sheet Metal /Black
No. of Loop 10 Loop Standalone Keypad 5 Brigade buttons and Programming Keypad
Protection Built-in 4kV Surge protection Display 7”TFT Touch Screen
Programmable Relays 4 circuits: Normally Open/Close Indicator 24 LED Status/ 160 Zone Indicators
Programmable Input 1 Circuit: Power limited 24VDC Fixed Outputs 2 Circuits:Power limited 18-28VDC
Programmable Aux Power Limited 19-28VDC    

PRODUCT & TECHNICAL SUPPORT

1-10 Loops 3-in-1 Fire Alarm Control Panel: FACP, FTS & FBS FAQs

Frequently asked questions about this product, configuration, compatibility and technical requirements.

01. What is the TANDA TX7008R intelligent addressable fire alarm control panel?

The TX7008R is a microprocessor-based analogue addressable fire alarm control panel with a modular rack-type design. It provides fire detection monitoring, alarm and fault indication, and programmable cause-and-effect control. The rack enclosure can also accommodate optional fire telephone and voice alarm equipment.

02. How many addressable loops and devices does the TX7008R support?

The TX7008R Installation and Operation Manual V1.0 specifies up to 8 addressable loops, with a maximum of 254 device addresses per loop and an ideal total capacity of 2,032 devices. FireMarket also offers information on 9–10-loop expansion configurations, which require confirmation against the applicable expanded-version documentation.

03. Can the TX7008R communicate with other fire alarm control panels?

Yes. The TX7008R supports panel-to-panel communication through CAN Bus when configured with 1–8 loops. According to FireMarket's additional configuration information, expanding the panel to 9 or 10 loops disables communication with other fire alarm control panels, requiring standalone operation. This expansion restriction is not documented in Manual V1.0 and should be verified for the applicable configuration.

04. Can the TX7008R integrate fire telephone and voice alarm systems?

Yes. The TX7008R rack enclosure provides space for optional TANDA TN7 fire telephone equipment and TANDA TG7 voice alarm equipment, allowing multiple fire safety systems to be housed in a single cabinet. These systems are optional and are not included in every standard TX7008R configuration.

05. Which addressable fire alarm devices are compatible with the TX7008R?

The TX7008R supports compatible T&A protocol addressable devices, including TX7100 smoke detectors, TX7110 heat detectors, TX7140 manual call points, TX7130 reflective beam detectors, TX7300 sounder strobes, TX7320 sounders, TX7200/TX7210/TX7220 interface modules, and TX7230 loop isolators. Device compatibility should be confirmed against the selected system configuration.

06. What display and control features does the TX7008R provide?

The TX7008R features a 7-inch TFT touchscreen, an operational and programming keypad, a built-in printer, 24 status LED indicators, and 160 zone LED indicators. The touchscreen and keypad provide alternative interfaces for system monitoring, configuration, and operation.

07. What commissioning features are available on the TX7008R fire alarm control panel?

The TX7008R supports automatic device enrollment, colour-coded loop mapping, duplicate address detection, device mismatch monitoring, one-man testing with sounder On/Off options, and programming protection. These functions help installers configure, test, and maintain the addressable fire alarm system.

08. Does the TX7008R support programmable cause-and-effect control?

Yes. The TX7008R includes a Command Builder function that allows programmed input conditions to activate specified outputs or output groups. The manufacturer documents elevator control, air-handling shutdown, gas shutoff, and damper control as examples of auxiliary functions that can be configured according to project-specific fire alarm cause-and-effect requirements.

09. How many programmable zones and groups does the TX7008R support?

According to the TX7008R Installation and Operation Manual V1.0, the panel supports up to 3,000 programmable zones and 3,000 programmable groups, including 1,000 sounder groups and 2,000 common groups. It also includes 160 zone LED indicators for visual status indication.

10. What power supply and backup battery configuration does the TX7008R require?

The TX7008R Installation and Operation Manual V1.0 specifies a 230 VAC, 50 Hz input supply with a +10%/-15% tolerance and supports two 12 V rechargeable lead-acid batteries with a maximum charging capacity of 45 Ah each. A separate product specification sheet lists 240 VAC, 50/60 Hz, so the applicable input rating should be confirmed for the supplied version. Standby batteries are not included with the panel, and the required battery capacity must be calculated according to the project load and standby requirements.

Related Products

FAQs

Q. Do you provide system design services?

A. Customization may be available for selected products. Feasibility, minimum quantities, costs and lead times depend on the product type and specific requirements

A. Yes. Share your BOQ, drawings or product list with quantities and technical requirements. We can help identify suitable products and prepare a quotation.

A. Compatibility cannot be assumed. It depends on the specific system, communication protocol and device models. Please contact us to verify before ordering.

Yes. Send us the product name, model, specifications or a reference photo, and we will check available sourcing options.

Yes. Send us the product name, model, specifications or a reference photo, and we will check available sourcing options.