1-10 Loops Fire Alarm Control Panel

The TX7008 Intelligent Addressable Fire Alarm Control Panel features a modular, microprocessor-based architecture for flexible system configuration and scalable fire protection.

Designed to meet BS EN 54-2 and EN 54-4 requirements, it provides early fire detection, accurate alarm-location identification, and customizable event messages.

Its programmable cause-and-effect functions enable coordinated evacuation and automatic control of building systems, including elevators, HVAC, gas shut-off valves, and fire dampers.

Brand:
Tanda UK
SKU:
TX7008
Loops:
8 (Expandable to 10)
Capacity:
Up to 2,540 Devices
Wiring:
Class A/B
Certification:
Complies with EN 54-2

Features and Benefits

• Compliance EN54-2 and EN54-4.
• Using advance microprocessor technology with Large memory capacity,
• Built-in USB port for commissioning purpose.
• Enhance user interface combining LCD Touch screen and keypad access.
• Support real time visual algorithm.
• Enhance false alarm prevention.
• Keypad and PC programming .
• Built-in Multiple interface protocol such as USB/Ethernet/CanBus/ Serial/RS485 (Available only in TX7004/4 Panel).
• Support Loop Powered devices for extra saving on cable cost.
• Built-In Printer and 160 LED Zones Indicators.

Commissioning Advantage

• Auto Enrolling of Devices.
• Loop Mapping with colour coding status.
• Monitor device mismatch and dual address conflict.
• Command Builder to create requirements for fire event scenario.
• With Loop protection against power surge
• One-man test with On/Off sounder Programming Protection.

System Capacity

• Maximum 8 loop in network application
• Support 254 Devices (1,524 ideal)
• Network up to 512 Node
• Programmable Capacity
• Zones up to 3000
• Sounders Groups 1-1000
• Modules Groups 1001- 2000
• Built-in 160 LED Zones Indicator

Input Voltage 230VAC +10%-15%,50Hz Humidity 0 to 95% Relative Humidity, Non condensing
Network Panel to panel 512 Panels- Single Ring[Ideal] Temperature -5℃~+40℃
Communication Card CanBus Weight 23Kg
Protocol/Addressing T&A, Value range from 1 to 254 Dimension/HWD 550 x 510 x 222mm
No. of Loop 6,8 Loop /10 Loop Standalone Material/Color Flat sheet Metal / with outer glass door,
Orange stripe
Protection Built-in 4kV Surge protection Keypad 5 Brigade buttons and Programming Keypad
Panel Input/outputs
Programmable Relays
4 circuits: Normally Open/Close Display 7”TFT Touch Screen
Programmable Input 1 Circuit: Power limited 24VDC Indicator 24 LED Status/ 160 Zone Indicators
Programmable Aux Power Limited 19-28VDC Fixed Outputs 2 Circuits:Power limited 18-28VDC

PRODUCT & TECHNICAL SUPPORT

1-10 Loops Fire Alarm Control Panel FAQs

Frequently asked questions about this product, configuration, compatibility and technical requirements.

01. What is the TANDA TX7008 intelligent addressable fire alarm control panel?

The TX7008 is a modular, microprocessor-based analogue addressable fire alarm control panel designed for fire detection, alarm monitoring, evacuation signalling and programmable building system control. It supports up to 8 addressable loops and provides a 7-inch TFT touchscreen, keypad operation, built-in printer and 160 LED zone indicators for system monitoring and operation.

02. How many loops and addressable devices does the TX7008 fire alarm control panel support?

The TX7008 supports up to 8 addressable detection loops, with a maximum of 254 device addresses per loop, providing a theoretical capacity of 2,032 addressable devices. The TX7008-6 variant supports 6 loops and up to 1,524 addresses. Actual device loading must consider loop current, cable length and system design requirements.

03. What is the difference between the TX7008 and TX7008-6 fire alarm control panels?

The TX7008 and TX7008-6 belong to the same intelligent addressable fire alarm control panel series. According to the datasheet, the TX7008 is fitted with four dual-loop cards for 8 loops and up to 2,032 addresses, while the TX7008-6 has three dual-loop cards for 6 loops and up to 1,524 addresses. Both feature a built-in communication card and 160 LED zone indicators.

04. Can the TX7008 fire alarm control panel be expanded with additional loop cards?

The TX7008 uses a modular loop card design. The LC7008 dual-loop card supports two addressable loops with a combined theoretical capacity of 508 devices. The datasheet lists LC7008 as an optional accessory for the TX7008-6 variant. Expansion must remain within the supported 8-loop system capacity and be verified against the selected panel configuration.

05. Does the TX7008 support CAN bus fire alarm panel networking?

Yes. The TX7008 supports panel-to-panel communication through CAN bus networking. The datasheet specifies a networking capacity of up to 512 panels using the NC7008 network card, while the installation manual's CAN bus wiring section describes connections for up to 99 networked fire alarm control panels. The applicable capacity should be confirmed for the selected network configuration and firmware.

06. Does the TX7008 support Ethernet, USB or other communication interfaces?

The TX7008 installation manual lists USB, Ethernet, RS232 and RS485 among its communication interfaces, while the datasheet identifies CAN bus for panel-to-panel networking and USB for programming. The manual marks TCP/IP setup and certain communication functions as intended for future use. Ethernet networking and third-party integration should therefore be confirmed for the specific hardware and firmware version rather than assumed as standard functions.

07. Which addressable fire alarm detectors and devices are compatible with the TX7008?

The TX7008 uses the T&A addressable protocol and supports compatible devices including TX7100 photoelectric smoke detectors, TX7110 heat detectors, TX7130 reflective beam detectors, TX7140 manual call points, TX7300 sounder strobes, TX7320 sounders, TX7200/TX7210/TX7220 input/output modules and TX7230 loop isolators. Device compatibility and electrical loading should be verified against the selected system configuration.

08. Can the TX7008 integrate with elevators, HVAC systems and other building equipment?

Yes. The TX7008 supports programmable cause-and-effect control through its Command Builder function. Using compatible interfaces and configured output logic, the system can coordinate functions such as elevator control, air-handling shutdown, gas shut-off and fire damper operation. The required control sequences are configured according to the project's fire alarm and building system requirements.

09. What programming and commissioning features does the TX7008 provide?

The TX7008 supports touchscreen, keypad and PC-based programming, with TX7810 software used to prepare and download project configurations. Commissioning functions include automatic device enrollment, color-coded loop mapping, duplicate address analysis, device mismatch monitoring, zone and group programming, and one-man testing. The panel also supports programmable cause-and-effect logic through Command Builder.

10. What are the maximum cable length and wiring requirements for TX7008 addressable loops?

The TX7008 datasheet specifies a maximum addressable loop cable length of 1,000 metres and recommends 2 × 1.5 mm² solid-core fire-resistant cable, subject to local installation codes. Each loop supports up to 254 device addresses and includes built-in 4 kV surge protection. Actual wiring design must account for loop loading, cable characteristics and applicable fire safety requirements.

11. What power supply and standby battery specifications does the TX7008 require?

The TX7008 uses a 230 VAC mains supply, with the installation manual specifying 50 Hz for the EN54/LPCB configuration. It supports rechargeable lead-acid standby batteries with a maximum stated capacity of 2 × 12 V/45 Ah. The batteries are not supplied with the panel. Required battery capacity must be calculated according to system loading, standby duration and local regulations.

12. Which EN54 standards does the TX7008 addressable fire alarm control panel comply with?

The TX7008 installation manual states compliance with EN54-2 for fire detection and fire alarm control and indicating equipment, and EN54-4 for power supply equipment. The documentation also references LPCB testing for the specified configuration. The 120 VAC/60 Hz supply option is explicitly excluded from the stated EN54 applicability and LPCB testing. Confirm the certification documents and approved configuration before ordering.

Related Products

FAQs

Q. Do you provide system design services?

A. Customization may be available for selected products. Feasibility, minimum quantities, costs and lead times depend on the product type and specific requirements

A. Yes. Share your BOQ, drawings or product list with quantities and technical requirements. We can help identify suitable products and prepare a quotation.

A. Compatibility cannot be assumed. It depends on the specific system, communication protocol and device models. Please contact us to verify before ordering.

Yes. Send us the product name, model, specifications or a reference photo, and we will check available sourcing options.

Yes. Send us the product name, model, specifications or a reference photo, and we will check available sourcing options.