Automatic Fire Monitor Water Jet Device 20S

The ZDMS0.8/20S-LZⅡ Automatic Fire Monitor is an automatic tracking and positioning fire-water cannon for fire protection in warehouses, factories, logistics centers, and other large indoor facilities. Featuring automatic fire-source positioning, adjustable nozzle direction, and remote or manual operation, the system supports targeted water discharge through coordinated fire water supply and electrical control equipment. It can be integrated with an electric control box, field operation panel, and central control host for centralized monitoring and operation.

Brand:
LinkZone
SKU:
ZDMS0.8/20S-LZⅡ
Certification:
HS250122, ICR, VC

INTERACTIVE SYSTEM PRINCIPLE

See How Automatic Targeting Works

An abstract spherical monitor illustrates scanning, fire-source positioning and directed water discharge. This is a conceptual animation, not a 3D model of the actual unit.

20 L/s · 42 m coverage Conceptual system visualization · not a mechanical drawing
SCANNING · Searching for a fire source
01 ScanMonitor surveys the area
02 LocateFire position is identified
03 DischargeDirected water jet is shown
04 SuppressFlame disappears in the simulation

Safety note: Actual pump and valve operation requires the prescribed control logic, onsite verification and qualified operator supervision. The animation is explanatory only.

ZDMS0.8/20S-LZⅡ 20 L/s automatic fire monitor showing metal mechanical pipe structure and motorized nozzleACTUAL PRODUCT · 20 L/s

INDUSTRIAL AUTOMATIC FIRE MONITOR

Built for Larger Spaces & Precise Targeting

The ZDMS0.8/20S-LZⅡ combines an exposed metal-body mechanical design, infrared thermal imaging guidance and motorized nozzle positioning for targeted water discharge in large indoor facilities.

20 L/sRated Flow
42 mProtection Radius
0.8 MPaWorking Pressure
Request Technical Support →
01

Metal-Body Mechanical Construction

Visible metal piping and mechanical drive components support a rugged industrial-style configuration. The exact alloy and corrosion rating should be confirmed against the ordered specification.

02

20 L/s Targeted Water Discharge

A 20 L/s rated flow at 0.8 MPa provides a 42 m protection radius for designated large-space applications.

03

360° Horizontal Positioning

Motorized 360° horizontal rotation and −90° to +30° vertical adjustment enable broad-direction aiming around the installed location.

04

Infrared Thermal Imaging Guidance

Infrared thermal imaging–based fire-source positioning supports automatic target guidance, with compatible remote and manual control.

HOW IT WORKS

How It Works

A four-stage overview of fire detection, target positioning and controlled water discharge.

1Detect Fire Source
Detect Fire Source – automatic fire monitor operating sequence

Infrared thermal imaging helps identify potential fire sources.

2Track Target
Track Target – automatic fire monitor operating sequence

The detection system determines the fire-source location.

3Aim Automatically
Aim Automatically – automatic fire monitor operating sequence

Motorized positioning turns the nozzle toward the selected target.

4Discharge Water
Discharge Water – automatic fire monitor operating sequence

Following the required operator verification and control sequence, water is directed toward the fire.

Fire Recognition & Targeting

Multi-sensor fire detection for more precise targeting and reduced false triggers.

FireMarket Recognition Technology

3-in-1 Precision Detection & Dynamic Tracking

UV Flame Detection IR Thermal Positioning VIS Visual Recognition

UV, infrared and visual inputs support fire-source localization, with moving-fire tracking available on supported configurations.

UV IR VIS

FireMarket 3-in-1 Recognition

Multiple sensing inputs help verify the fire location before discharge.

Single-Cue Recognition

Unverified visual cues may lead to false detection and unintended discharge.

✕ False Trigger Examples

false-trigger-screen

Flames on a Digital Screen

A flame video is mistaken for a real fire, causing unwanted discharge.

false-trigger-led

Red LED Warning Light

A warning light is mistaken for a flame, triggering an unwanted water discharge.

Illustrative false-trigger scenarios. Actual discharge depends on the configured detection and release logic.

FREE PRELIMINARY LAYOUT SUPPORT

Planning Coverage Before Finalizing Your Project?

Not sure how many fire monitors you need or where they should be installed? Share a floor plan and FireMarket can help prepare a free preliminary reference layout for scope discussion and budget evaluation.

Request a Free Preliminary Layout →

What to send us

✓ Building use and location

✓ Floor plans or approximate dimensions

✓ Ceiling heights and known obstacles

✓ Available fire water supply information

Preliminary layouts are for initial evaluation and budgeting, not construction or code-compliance approval.

SPECIFICATIONS & SYSTEM

Designed to Work as a Complete System

Confirmed Technical Parameters

ModelZDMS0.8/20S-LZⅡ
Rated Flow20 L/s
Protection Radius42 m
Working Pressure0.8 MPa
Working VoltageDC 24–36 V
Horizontal Rotation360°
Vertical Rotation−90° to +30°
Dimensions550 × 550 × 550 mm
Weight22 kg

Integration & Operation

System configuration may include compatible electric control boxes, field operation panels, a central control host and a designed fire water supply. The monitor itself is one component within this coordinated installation.

⌁Water SupplyPump & piping
▣Control HostSupervision
▤Field PanelLocal operation
◎Fire MonitorTargeted jet

Illustrative components; actual hydraulic and electrical connections must follow approved project drawings and the correct model manuals. The manufacturer manual provided contains mixed model references and should not be used to infer unverified specifications for this unit.

APPLICATIONS

Large Indoor Spaces That Need Directed Coverage

Selection and layout depend on building geometry, obstructions, fire hazards and applicable local design requirements.

Warehouses large indoor fire monitor application setting
Warehouses

Racked storage and wide aisles

Factories & Workshops large indoor fire monitor application setting
Factories & Workshops

Production halls and manufacturing areas

Logistics Centers large indoor fire monitor application setting
Logistics Centers

Sorting, handling and distribution facilities

Large Indoor Facilities large indoor fire monitor application setting
Large Indoor Facilities

Exhibition halls and other open-span spaces

Additional information

Certification

HS250122, ICR, VC

Model ZDMS0.8/20S-LZⅡ
Rated Flow 20 L/s
Protection Radius 42 m
Working Pressure 0.8 MPa
Working Voltage DC 24–36 V
Working Current ≤ 1 A
Monitoring Current ≤ 100 mA
Operating Environment 4–55°C, ≤ 95% RH
Horizontal Rotation 360°
Vertical Rotation −90° to +30°
Dimensions (L × W × H) 550 × 550 × 550 mm
Weight 22 kg

PRODUCT & TECHNICAL SUPPORT

Automatic Fire Monitor Water Jet Device 20S FAQs

Frequently asked questions about this product, configuration, compatibility and technical requirements.

01. What is the ZDMS0.8/20S-LZII?

The ZDMS0.8/20S-LZII is a fixed water jet device designed to deliver a rated flow of 20 L/s at a working pressure of 0.8 MPa. It is the external-valve LZII configuration and is intended for use as part of an engineered fire protection system.

02. What is the rated flow of the ZDMS0.8/20S-LZII?

The rated flow is 20 L/s, equivalent to 1,200 L/min. The water supply and pipework must be hydraulically designed to provide this flow at the required working pressure.

03. What is the protection radius of the ZDMS0.8/20S-LZII?

The specified protection radius is 42 m. Actual project coverage must be verified against the approved layout, installation conditions, obstructions, and applicable local requirements.

04. What is the monitoring radius of the ZDMS0.8/20S-LZII?

The specified monitoring radius is 60 m. This is different from the 42 m protection radius and should not be used as the water-discharge coverage distance.

05. What working pressure does the ZDMS0.8/20S-LZII require?

The specified working pressure is 0.8 MPa. System designers should confirm that the available pressure and flow at the device meet this requirement under the approved hydraulic design.

06. What installation height is specified for the ZDMS0.8/20S-LZII?

The specified installation height range is 8 m to 35 m. The final mounting height must also comply with the approved fire protection design, site conditions, and local regulations.

07. How quickly can the ZDMS0.8/20S-LZII complete a scan?

The specified scanning time is no more than 60 seconds. This value refers to scanning and does not represent the total time required to control or extinguish a fire.

08. Does the ZDMS0.8/20S-LZII use an external valve?

Yes. The LZII version is an external-valve configuration. The exact valve, control components, and accessories included in a supplied package should be confirmed before ordering.

09. Can the ZDMS0.8/20S-LZII be controlled manually?

Yes. The device can be manually operated through the control host and the field operation panel, allowing the operator to adjust the jet direction and initiate the required system actions.

10. Can the ZDMS0.8/20S-LZII be controlled remotely?

Yes. Remote operation is available through the associated control host when the system is correctly connected and configured. The final control architecture should follow the approved project design.

11. Does the ZDMS0.8/20S-LZII provide automatic fire detection and discharge?

The available product information identifies an automatic operating mode and a scanning-time specification, but it does not clearly confirm the detection technology or the complete automatic-discharge logic for this exact model. Obtain written confirmation of the required automatic functions before specifying or ordering the system.

12. How should the ZDMS0.8/20S-LZII be mounted?

The device is intended for vertical downward installation. The upstream pipe should be securely fixed to a wall, column, or steel structure, and the side marked to face the wall must be oriented accordingly.

13. How much clearance does the ZDMS0.8/20S-LZII require?

Keep at least 40 cm between the device and surrounding obstructions, and ensure that it can rotate through an unobstructed 360 degrees. The approved installation drawing and site conditions may require additional clearance.

14. Is a strainer required for the ZDMS0.8/20S-LZII?

Yes. A strainer is required in the upstream water pipe to help prevent debris from entering the device. The pipeline should also be pressure-tested and flushed before the external valve and device are placed in service.

15. What wiring is used for the ZDMS0.8/20S-LZII?

The documented connection arrangement is 4+2+1: four power conductors, two signal conductors, and one video connection. Cable selection, routing, and termination must follow the approved project design and local electrical requirements.

16. Can more than 32 ZDMS0.8/20S-LZII devices be connected to one system?

A system with more than 32 devices requires additional signal and power circuits to the control host. The permitted number per circuit and the total system capacity should be confirmed for the selected control configuration.

17. How is the ZDMS0.8/20S-LZII identified in the control system?

The device uses a four-digit product ID consisting of an area code and a location code. Each installed device should have a unique ID that matches the approved system configuration and site records.

18. Can the ZDMS0.8/20S-LZII be used with foam solution?

Foam compatibility is not confirmed for this exact model in the available product information. Do not use foam solution unless the manufacturer provides written confirmation covering the foam type, concentration, materials compatibility, and system configuration.

19. What IP rating and outdoor suitability does the ZDMS0.8/20S-LZII have?

An exact IP rating and unrestricted outdoor suitability are not confirmed for this model in the available product information. Confirm the required environmental protection, enclosure measures, temperature range, and corrosion protection in writing for the intended site.

20. How often should the ZDMS0.8/20S-LZII be inspected and maintained?

Manufacturer guidance includes regular manual operation, periodic checks of local and remote functions, cleaning and lubrication according to site contamination, annual terminal-voltage checks, and simulated system tests. These are product-based recommendations only; the actual inspection, testing, and maintenance schedule must follow local regulations, the approved system design, site conditions, and the approved maintenance plan.

Free Preliminary System Drawings

Working on a project budget without a system layout? FireMarket provides free preliminary drawings to help you estimate equipment quantities and costs.

Request Free Preliminary Drawings