Peranti Pancutan Air 20S

Monitor air pemadam kebakaran automatik ZDMS0.8/20S-LZⅡ direka untuk penjejakan dan penentuan kedudukan punca kebakaran di gudang, kilang, pusat logistik serta kemudahan dalaman yang besar. Dengan penentuan lokasi punca kebakaran secara automatik, arah muncung boleh laras dan operasi jauh atau manual, sistem ini menyokong pancutan air bersasar melalui bekalan air kebakaran dan peralatan kawalan elektrik yang diselaraskan. Ia boleh diintegrasikan dengan kotak kawalan elektrik, panel operasi di lokasi dan hos kawalan pusat untuk pemantauan dan operasi berpusat.

Jenama:
LinkZone
SKU:
ZDMS0.8/20S-LZⅡ
Pensijilan:
HS250122, ICR, VC

INTERACTIVE SYSTEM PRINCIPLE

See How Automatic Targeting Works

An abstract spherical monitor illustrates scanning, fire-source positioning and directed water discharge. This is a conceptual animation, not a 3D model of the actual unit.

20 L/s · 42 m coverage Conceptual system visualization · not a mechanical drawing
SCANNING · Searching for a fire source
01 ImbasMonitor surveys the area
02 Cari LokasiFire position is identified
03 PancutkanDirected water jet is shown
04 PadamkanFlame disappears in the simulation

Safety note: Actual pump and valve operation requires the prescribed control logic, onsite verification and qualified operator supervision. The animation is explanatory only.

ZDMS0.8/20S-LZⅡ 20 L/s automatic fire monitor showing metal mechanical pipe structure and motorized nozzleACTUAL PRODUCT · 20 L/s

INDUSTRIAL AUTOMATIC FIRE MONITOR

Built for Larger Spaces & Precise Targeting

Modul Antara Muka Beralamat ZDMS0.8/20S-LZⅡ combines an exposed metal-body mechanical design, infrared thermal imaging guidance and motorized nozzle positioning for targeted water discharge in large indoor facilities.

20 L/sKadar aliran terkadar
42 mJejari perlindungan
0.8 MPaTekanan operasi
Minta Sokongan Teknikal →
01

Metal-Body Mechanical Construction

Visible metal piping and mechanical drive components support a rugged industrial-style configuration. The exact alloy and corrosion rating should be confirmed against the ordered specification.

02

20 L/s Targeted Water Discharge

A 20 L/s rated flow at 0.8 MPa provides a 42 m protection radius for designated large-space applications.

03

360° Horizontal Positioning

Motorized 360° horizontal rotation and −90° to +30° vertical adjustment enable broad-direction aiming around the installed location.

04

Infrared Thermal Imaging Guidance

Infrared thermal imaging–based fire-source positioning supports automatic target guidance, with compatible remote and manual control.

HOW IT WORKS

Cara Ia Berfungsi

A four-stage overview of fire detection, target positioning and controlled water discharge.

1Kesan Punca Kebakaran
Detect Fire Source – automatic fire monitor operating sequence

Infrared thermal imaging helps identify potential fire sources.

2Jejak Sasaran
Track Target – automatic fire monitor operating sequence

The detection system determines the fire-source location.

3Halakan Secara Automatik
Aim Automatically – automatic fire monitor operating sequence

Motorized positioning turns the nozzle toward the selected target.

4Pancut Air
Discharge Water – automatic fire monitor operating sequence

Following the required operator verification and control sequence, water is directed toward the fire.

Pengecaman Kebakaran & Sasaran

Multi-sensor fire detection for more precise targeting and reduced false triggers.

FireMarket Recognition Technology

3-in-1 Precision Detection & Dynamic Tracking

UV Pengesanan Nyalaan IR Penentuan Kedudukan Terma VIS Pengecaman Visual

UV, infrared and visual inputs support fire-source localization, with moving-fire tracking available on supported configurations.

UV IR VIS

FireMarket 3-in-1 Recognition

Multiple sensing inputs help verify the fire location before discharge.

Single-Cue Recognition

Unverified visual cues may lead to false detection and unintended discharge.

✕ False Trigger Examples

false-trigger-screen

Flames on a Digital Screen

A flame video is mistaken for a real fire, causing unwanted discharge.

false-trigger-led

Red LED Warning Light

A warning light is mistaken for a flame, triggering an unwanted water discharge.

Illustrative false-trigger scenarios. Actual discharge depends on the configured detection and release logic.

FREE PRELIMINARY LAYOUT SUPPORT

Planning Coverage Before Finalizing Your Project?

Not sure how many fire monitors you need or where they should be installed? Share a floor plan and FireMarket can help prepare a free preliminary reference layout for scope discussion and budget evaluation.

Request a Free Preliminary Layout →

Maklumat yang Perlu Dihantar

✓ Building use and location

✓ Floor plans or approximate dimensions

✓ Ceiling heights and known obstacles

✓ Available fire water supply information

Preliminary layouts are for initial evaluation and budgeting, not construction or code-compliance approval.

SPECIFICATIONS & SYSTEM

Designed to Work as a Complete System

Confirmed Technical Parameters

ModelZDMS0.8/20S-LZⅡ
Kadar aliran terkadar20 L/s
Jejari perlindungan42 m
Tekanan operasi0.8 MPa
Voltan operasiDC 24–36 V
Putaran mendatar360°
Putaran menegak−90° to +30°
Dimensi550 × 550 × 550 mm
Berat22 kg

Integration & Operation

System configuration may include compatible electric control boxes, field operation panels, a central control host and a designed fire water supply. The monitor itself is one component within this coordinated installation.

⌁Bekalan AirPam dan Paip
▣Hos Kawalan PusatPenyeliaan
▤Panel TapakOperasi Setempat
◎Monitor Air Pemadam KebakaranPancutan Bersasar

Illustrative components; actual hydraulic and electrical connections must follow approved project drawings and the correct model manuals. The manufacturer manual provided contains mixed model references and should not be used to infer unverified specifications for this unit.

APPLICATIONS

Large Indoor Spaces That Need Directed Coverage

Selection and layout depend on building geometry, obstructions, fire hazards and applicable local design requirements.

Warehouses large indoor fire monitor application setting
Gudang

Racked storage and wide aisles

Factories & Workshops large indoor fire monitor application setting
Factories & Workshops

Production halls and manufacturing areas

Logistics Centers large indoor fire monitor application setting
Pusat Logistik

Sorting, handling and distribution facilities

Large Indoor Facilities large indoor fire monitor application setting
Large Indoor Facilities

Exhibition halls and other open-span spaces

Additional information

Certification

HS250122, ICR, VC

Model ZDMS0.8/20S-LZⅡ
Kadar aliran terkadar 20 L/s
Jejari perlindungan 42 m
Tekanan operasi 0.8 MPa
Voltan operasi DC 24–36 V
Arus operasi ≤ 1 A
Arus pemantauan ≤ 100 mA
Persekitaran operasi 4–55°C, ≤ 95% RH
Putaran mendatar 360°
Putaran menegak −90° to +30°
Dimensi (P × L × T) 550 × 550 × 550 mm
Berat 22 kg