Explosion-Proof Water Monitor 20–60 L/s

La serie de monitores de agua fijos antideflagrantes PSKD ofrece cinco modelos con caudales nominales de 20–60 L/s y alcances de chorro de 47–78 m, diseñados para aplicaciones industriales de protección contra incendios que requieren equipos antideflagrantes. Incorpora operación remota, rotación horizontal de 360° y patrones ajustables de chorro compacto y niebla de agua, permitiendo la extinción dirigida mediante la integración con sistemas de suministro de agua y control compatibles.

Marca:
LinkZone
Certificación:
ICR/VC/HS250122
Explosion-proof fixed water monitor, representative 20–60 L/s product, front view
Explosion-Proof Fixed Water Monitor · Representative Model

EXPLOSION-PROOF FIRE PROTECTION

Explosion-Proof Fixed Water Monitors for Industrial Fire Protection

El Explosion-Proof Fixed Water Monitors are available in five remotely controlled configurations rated from 20 to 60 L/s, with catalogue-listed jet radii of 47–78 m. Built for industrial projects with explosion-protection considerations, the range combines metal mechanical assemblies, 360° horizontal positioning and selectable water-column or fog discharge. Verify the supplied unit’s Ex certification and hazardous-area suitability before selection.

20–60 L/sRated Flow Range
47–78 mJet Radius Range
5 Models20 / 30 / 40 / 50 / 60 L/s
Request Series Catalogue & Ex Documents

Explosion-proof classification and suitability for a particular hazardous area must be verified using the actual model certificates, markings and project requirements.

Core product differentiation

Explosion-Proof Design for Demanding Industrial Environments

Unlike standard fixed water monitors, these models are manufacturer-designated explosion-proof equipment for industrial firefighting projects. Explosion-protection suitability must be assessed against the exact supplied model, certified components, equipment marking and complete installation.

Explosion-proof fixed water monitor metal pipework, drive assembly, nozzle and mounting flange
Explosion-proof fixed water monitor · confirm the supplied model’s certified marking

Construction & selection

Industrial Metal Assembly with Remote-Controlled Positioning

Visible metal water passages, flanged joints and actuator housings distinguish this fixed monitor's industrial mechanical layout. Its remotely controlled design allows the operator to aim the monitor from compatible control equipment instead of working directly at the discharge location.

01
Manufacturer-Designated Ex Series

Designed as an explosion-proof product range; confirm the exact Ex marking, certificates, zone or division classification and installation conditions for the selected model.

02
Mechanical & Electrical Construction

Metal pipework and enclosed actuator components are visible, but appearance alone does not establish flameproof construction, ingress protection or a particular certification.

03
Remote Operation in Industrial Systems

Control via compatible field operation panels and control hosts supports directional adjustment and operator-supervised water discharge.

Before specifying this series for a hazardous area:Request model-specific certificates, Ex markings and installation instructions; confirm applicable gas/dust group, temperature class and certified equipment scope, including electrical control components and wiring accessories.

Five-Model Comparison

Explosion-Proof Fixed Water Monitor Specifications

Compare the full fixed water monitor range. On mobile, swipe horizontally to view all five models.

ParámetroPSKD8/20WGPSKD8/30WGPSKD8/40WGPSKD8/50WGPSKD10/60WG
Caudal nominal20 L/s30 L/s40 L/s50 L/s60 L/s
Alcance del chorro47 m56 m58 m62 m78 m
Presión de trabajo0.8 MPa0.8 MPa0.8 MPa0.8 MPa1.0 MPa
Tensión de funcionamientoDC 24–36 V
Corriente de funcionamiento≤ 1 A
Corriente de supervisión≤ 100 mA
Entorno de funcionamiento4–55°C, ≤ 95% RH
Rotación horizontal360°
Rotación vertical−90° to +30°
Dimensiones (L × An × Al)600 × 600 × 680 mm
Peso35 kg
Patrón de descargaChorro compacto / niebla
Método de controlOperación remota mediante panel compatible

Jet radii follow the supplied five-model product catalogue. A separate PSKD8/30WG instruction manual lists 60 m rather than 56 m; confirm the applicable test condition and rated jet radius with the manufacturer before final specification.

DC 24–36 VTensión de funcionamiento
360°Rotación horizontal
−90° to +30°Rotación vertical
Column / FogSelectable Spray Patterns

Firefighting Performance

Remote Control, Spray Flexibility & Broad Coverage

In addition to explosion-proof product positioning, the five configurations offer remote operation, adjustable discharge patterns and wide-angle aiming. Verify the specific Ex certification for the model and installation area.

01

20–60 L/s Flow Options

Choose from five rated-flow configurations to match project hydraulic design and required firefighting capacity.

02

Operación por control remoto

Direction and discharge can be managed using compatible field operation panels and control hosts, following the required operator procedures.

03

Water Column & Fog

Switch between a concentrated straight water stream and a diffused spray pattern as supported by the system configuration.

04

360° Horizontal Rotation

Motorized horizontal traverse and −90° to +30° vertical adjustment support wide-direction aiming around the fixed installation.

05

Metal Mechanical Construction

Visible metal waterways, flanges and motorized housings provide an industrial mechanical assembly. Confirm material grade and protection details for each quoted configuration.

Discharge Patterns

Straight-Stream and Fog Spray Modes

Two illustrations explain the available water discharge patterns. Spray geometry is illustrative; actual performance depends on the specified model and water supply conditions.

Water Column · Concentrated Jet

A more concentrated stream is intended for directed water projection toward a selected area.

Fog · Diffused Spray

A wider, diffused pattern can be selected for the intended firefighting strategy and hydraulic conditions.

Integración del sistema

One Monitor in a Coordinated Fire Protection System

A fixed water monitor is supplied as part of a designed system that includes sufficient water supply and appropriate control equipment. The sequence below indicates components, not the actual wiring or piping order.

≈Fire Water SupplyTank, pump, pipework and valves
▣Control eléctricoCompatible control box and power
▤Operation PanelRemote manual aiming and control
◎Fixed Water MonitorPositioning and water discharge

Manufacturer instructions require operator checks before valve activation, a clear water path and proper professional wiring. Hazardous-area system suitability must be reviewed against applicable certifications and local requirements.

Project Applications

Fixed Fire Monitor Options for Demanding Industrial Areas

The following are potential project contexts for technical evaluation, not blanket claims of certification for every classified area.

Instalaciones de procesamiento químico

Industrial production and processing areas requiring directed firefighting coverage.

Instalaciones de petróleo y gas

Selected process or storage areas subject to site-specific risk and hazardous-area assessments.

Almacenamiento industrial y almacenes

Large open spaces where hydraulic capacity and jet radius influence monitor selection.

Plantas de industria pesada

Industrial facilities needing remotely controlled fire water monitors and coordinated control systems.

FireMarket · B2B Project Sourcing

Need an Explosion-Proof Water Monitor for Your Project?

Compare the 20, 30, 40, 50 and 60 L/s configurations, or send us your project drawings, required flow and pressure, location and explosion-protection criteria. FireMarket can help source the relevant product documents and prepare a free preliminary reference layout for budgeting and scope evaluation.

Get a Free Preliminary Layout →

Comparta sus requisitos

✓ Preferred flow: 20 / 30 / 40 / 50 / 60 L/s

✓ Required jet radius and available water pressure

✓ Hazardous-area classification and Ex certification needs

✓ Installation drawings, control requirements and site country

Preliminary layouts are for initial discussion and budget estimation, not construction or regulatory approval.

Productos relacionados

Preguntas frecuentes

P. ¿Ofrecen servicios de diseño de sistemas?

R. La personalización puede estar disponible para determinados productos. La viabilidad, las cantidades mínimas, los costes y los plazos de entrega dependen del tipo de producto y de los requisitos específicos

R. Sí. Comparta su lista de materiales (BOQ), planos o lista de productos con las cantidades y especificaciones técnicas. Podemos ayudarle a identificar los productos adecuados y preparar un presupuesto.

R. No se puede asumir la compatibilidad. Depende del sistema específico, del protocolo de comunicación y de los modelos de los dispositivos. Póngase en contacto con nosotros para verificarlo antes de cursar su pedido.

Sí. Envíenos el nombre del producto, modelo, especificaciones o una fotografía de referencia y comprobaremos las opciones de suministro disponibles.

Sí. Envíenos el nombre del producto, modelo, especificaciones o una fotografía de referencia y comprobaremos las opciones de suministro disponibles.