Explosion-Proof Water Monitor 20–60 L/s

The PSKD Explosion-Proof Fixed Water Monitor Series offers five models with rated flows of 20–60 L/s and jet radii of 47–78 m, designed for industrial fire protection applications requiring explosion-proof equipment. Featuring remote-controlled operation, 360° horizontal rotation, and adjustable water column and fog discharge patterns, the series supports targeted firefighting through integration with compatible water supply and control systems.

Brand:
LinkZone
Certification:
ICR/VC/HS250122
Product Type:
Explosion-Proof Fixed Water Monitor
Rated Flow:
20–60 L/s
PSKD8/30WG
PSKD8/30WG
PSKD8/40WG
PSKD8/40WG
PSKD8/50WG
PSKD8/50WG
PSKD10/60WG
PSKD10/60WG
Explosion-proof fixed water monitor, representative 20–60 L/s product, front view
Explosion-Proof Fixed Water Monitor · Representative Model

EXPLOSION-PROOF FIRE PROTECTION

Explosion-Proof Fixed Water Monitors for Industrial Fire Protection

The Explosion-Proof Fixed Water Monitors are available in five remotely controlled configurations rated from 20 to 60 L/s, with catalogue-listed jet radii of 47–78 m. Built for industrial projects with explosion-protection considerations, the range combines metal mechanical assemblies, 360° horizontal positioning and selectable water-column or fog discharge. Verify the supplied unit’s Ex certification and hazardous-area suitability before selection.

20–60 L/sRated Flow Range
47–78 mJet Radius Range
5 Models20 / 30 / 40 / 50 / 60 L/s
Request Series Catalogue & Ex Documents

Explosion-proof classification and suitability for a particular hazardous area must be verified using the actual model certificates, markings and project requirements.

Core product differentiation

Explosion-Proof Design for Demanding Industrial Environments

Unlike standard fixed water monitors, these models are manufacturer-designated explosion-proof equipment for industrial firefighting projects. Explosion-protection suitability must be assessed against the exact supplied model, certified components, equipment marking and complete installation.

Explosion-proof fixed water monitor metal pipework, drive assembly, nozzle and mounting flange
Explosion-proof fixed water monitor · confirm the supplied model’s certified marking

Construction & selection

Industrial Metal Assembly with Remote-Controlled Positioning

Visible metal water passages, flanged joints and actuator housings distinguish this fixed monitor's industrial mechanical layout. Its remotely controlled design allows the operator to aim the monitor from compatible control equipment instead of working directly at the discharge location.

01
Manufacturer-Designated Ex Series

Designed as an explosion-proof product range; confirm the exact Ex marking, certificates, zone or division classification and installation conditions for the selected model.

02
Mechanical & Electrical Construction

Metal pipework and enclosed actuator components are visible, but appearance alone does not establish flameproof construction, ingress protection or a particular certification.

03
Remote Operation in Industrial Systems

Control via compatible field operation panels and control hosts supports directional adjustment and operator-supervised water discharge.

Before specifying this series for a hazardous area:Request model-specific certificates, Ex markings and installation instructions; confirm applicable gas/dust group, temperature class and certified equipment scope, including electrical control components and wiring accessories.

Five-Model Comparison

Explosion-Proof Fixed Water Monitor Specifications

Compare the full fixed water monitor range. On mobile, swipe horizontally to view all five models.

ParameterPSKD8/20WGPSKD8/30WGPSKD8/40WGPSKD8/50WGPSKD10/60WG
Rated Flow20 L/s30 L/s40 L/s50 L/s60 L/s
Jet Radius47 m56 m58 m62 m78 m
Working Pressure0.8 MPa0.8 MPa0.8 MPa0.8 MPa1.0 MPa
Working VoltageDC 24–36 V
Working Current≤ 1 A
Monitoring Current≤ 100 mA
Operating Environment4–55°C, ≤ 95% RH
Horizontal Rotation360°
Vertical Rotation−90° to +30°
Dimensions (L × W × H)600 × 600 × 680 mm
Weight35 kg
Discharge PatternWater Column / Fog
Control MethodRemote Operation via Compatible Panel

Jet radii follow the supplied five-model product catalogue. A separate PSKD8/30WG instruction manual lists 60 m rather than 56 m; confirm the applicable test condition and rated jet radius with the manufacturer before final specification.

DC 24–36 VWorking Voltage
360°Horizontal Rotation
−90° to +30°Vertical Rotation
Column / FogSelectable Spray Patterns

Firefighting Performance

Remote Control, Spray Flexibility & Broad Coverage

In addition to explosion-proof product positioning, the five configurations offer remote operation, adjustable discharge patterns and wide-angle aiming. Verify the specific Ex certification for the model and installation area.

01

20–60 L/s Flow Options

Choose from five rated-flow configurations to match project hydraulic design and required firefighting capacity.

02

Remote-Controlled Operation

Direction and discharge can be managed using compatible field operation panels and control hosts, following the required operator procedures.

03

Water Column & Fog

Switch between a concentrated straight water stream and a diffused spray pattern as supported by the system configuration.

04

360° Horizontal Rotation

Motorized horizontal traverse and −90° to +30° vertical adjustment support wide-direction aiming around the fixed installation.

05

Metal Mechanical Construction

Visible metal waterways, flanges and motorized housings provide an industrial mechanical assembly. Confirm material grade and protection details for each quoted configuration.

Discharge Patterns

Straight-Stream and Fog Spray Modes

Two illustrations explain the available water discharge patterns. Spray geometry is illustrative; actual performance depends on the specified model and water supply conditions.

Water Column · Concentrated Jet

A more concentrated stream is intended for directed water projection toward a selected area.

Fog · Diffused Spray

A wider, diffused pattern can be selected for the intended firefighting strategy and hydraulic conditions.

System Integration

One Monitor in a Coordinated Fire Protection System

A fixed water monitor is supplied as part of a designed system that includes sufficient water supply and appropriate control equipment. The sequence below indicates components, not the actual wiring or piping order.

≈Fire Water SupplyTank, pump, pipework and valves
▣Electrical ControlCompatible control box and power
▤Operation PanelRemote manual aiming and control
◎Fixed Water MonitorPositioning and water discharge

Manufacturer instructions require operator checks before valve activation, a clear water path and proper professional wiring. Hazardous-area system suitability must be reviewed against applicable certifications and local requirements.

Project Applications

Fixed Fire Monitor Options for Demanding Industrial Areas

The following are potential project contexts for technical evaluation, not blanket claims of certification for every classified area.

Chemical Processing Facilities

Industrial production and processing areas requiring directed firefighting coverage.

Oil & Gas Facilities

Selected process or storage areas subject to site-specific risk and hazardous-area assessments.

Industrial Storage & Warehouses

Large open spaces where hydraulic capacity and jet radius influence monitor selection.

Heavy Industrial Plants

Industrial facilities needing remotely controlled fire water monitors and coordinated control systems.

FireMarket · B2B Project Sourcing

Need an Explosion-Proof Water Monitor for Your Project?

Compare the 20, 30, 40, 50 and 60 L/s configurations, or send us your project drawings, required flow and pressure, location and explosion-protection criteria. FireMarket can help source the relevant product documents and prepare a free preliminary reference layout for budgeting and scope evaluation.

Get a Free Preliminary Layout →

Share your requirements

✓ Preferred flow: 20 / 30 / 40 / 50 / 60 L/s

✓ Required jet radius and available water pressure

✓ Hazardous-area classification and Ex certification needs

✓ Installation drawings, control requirements and site country

Preliminary layouts are for initial discussion and budget estimation, not construction or regulatory approval.

PRODUCT & TECHNICAL SUPPORT

Explosion-Proof Water Monitor 20–60 L/s FAQs

Frequently asked questions about this product, configuration, compatibility and technical requirements.

01. What models are available in the PSKDWG explosion-proof fixed water monitor series?

The series includes PSKD8/20WG, PSKD8/30WG, PSKD8/40WG, PSKD8/50WG, and PSKD10/60WG, providing five rated-flow options from 20 L/s to 60 L/s.

02. What is the rated flow range of the PSKDWG explosion-proof fixed water monitors?

The series covers rated flows from 20 L/s to 60 L/s. The available capacities are 20 L/s, 30 L/s, 40 L/s, 50 L/s, and 60 L/s, depending on the selected model.

03. What jet radius is available from the PSKDWG series?

The specified jet radius ranges from 47 m to 78 m. The PSKD8/20WG reaches 47 m, PSKD8/30WG 56 m, PSKD8/40WG 58 m, PSKD8/50WG 62 m, and PSKD10/60WG 78 m.

04. What are the main specifications of the PSKD8/20WG?

The PSKD8/20WG has a rated flow of 20 L/s, a specified jet radius of 47 m, and a working pressure of 0.8 MPa.

05. What are the main specifications of the PSKD8/30WG?

The PSKD8/30WG has a rated flow of 30 L/s, a specified jet radius of 56 m, and a working pressure of 0.8 MPa.

06. What are the main specifications of the PSKD8/40WG?

The PSKD8/40WG has a rated flow of 40 L/s, a specified jet radius of 58 m, and a working pressure of 0.8 MPa.

07. What are the main specifications of the PSKD8/50WG?

The PSKD8/50WG has a rated flow of 50 L/s, a specified jet radius of 62 m, and a working pressure of 0.8 MPa.

08. What are the main specifications of the PSKD10/60WG?

The PSKD10/60WG has a rated flow of 60 L/s, a specified jet radius of 78 m, and a working pressure of 1.0 MPa.

09. Do all PSKDWG explosion-proof fixed water monitors use the same working pressure?

No. The 20 L/s, 30 L/s, 40 L/s, and 50 L/s models have a specified working pressure of 0.8 MPa, while the 60 L/s PSKD10/60WG requires 1.0 MPa.

10. How should I select a PSKDWG fixed water monitor model?

Select the model according to the required flow, jet radius, available water pressure, hydraulic calculations, protected hazard, installation position, and approved fire protection design. Higher flow does not automatically make a model suitable for every project.

11. Can the PSKDWG monitors discharge both a water jet and water fog?

Yes. The series supports both a concentrated water jet and a fog pattern. The appropriate pattern should be selected according to the fire scenario, required reach, exposure-cooling needs, and approved firefighting strategy.

12. How are the PSKDWG explosion-proof fixed water monitors controlled?

The monitors are remotely controlled through an associated operation panel, allowing the operator to aim the monitor and select the required discharge pattern from the designated control position.

13. Why is remote control important for these explosion-proof water monitors?

Remote control reduces the need for personnel to approach the monitor during a fire in a potentially hazardous location. The operation panel should be installed in a position permitted by the approved hazardous-area and fire protection design.

14. What is the explosion-proof advantage of the PSKDWG series?

The explosion-proof configuration is intended for applications where flammable gases, vapors, dust, or similar hazardous conditions may make ordinary electrical equipment unsuitable. Final suitability depends on matching the confirmed explosion-protection marking to the site classification.

15. Can a PSKDWG monitor be installed in any hazardous area?

No. The product’s explosion-protection marking, gas or dust group, temperature class, equipment protection level, ambient limits, and permitted zone must match the approved hazardous-area classification.

16. What explosion-proof rating does the PSKDWG series have?

The exact explosion-protection marking and certification details are not confirmed in the available information. Obtain the applicable nameplate data and certificate before selecting any model for a classified hazardous area.

17. Is the operation panel also explosion-proof?

The explosion-protection status of the operation panel is not confirmed in the available information. If it will be installed inside a classified area, its certification and environmental suitability must be verified separately.

18. What power supply do the PSKDWG monitors require?

The specified working voltage is DC 24–36 V. The power supply, cables, glands, junction boxes, grounding, sealing methods, voltage drop, and circuit protection must comply with the approved electrical and hazardous-area design.

19. What are the working and monitoring currents of the PSKDWG series?

The specified working current is no more than 1 A, and the monitoring current is no more than 100 mA. Power-supply calculations should cover both monitoring and full operating conditions.

20. What movement range do the PSKDWG fixed water monitors provide?

The specified horizontal rotation is 360 degrees, and the vertical rotation range is from -90 degrees to +30 degrees. The installation must provide unobstructed clearance throughout the required movement range.

21. What operating environment is specified for the PSKDWG series?

The specified operating environment is 4°C to 55°C with relative humidity not exceeding 95%. These limits do not independently confirm suitability for every outdoor, corrosive, marine, or hazardous environment.

22. What are the dimensions and weight of the PSKDWG monitors?

The specified overall dimensions are 600 × 600 × 680 mm, and the specified weight is 35 kg. The supporting structure must also accommodate pipe loads and reaction forces during discharge.

23. What water supply is required for a PSKDWG monitor?

The water supply must provide the selected model’s rated flow at its specified working pressure. Pipe diameter, pump capacity, friction loss, simultaneous operation, and available pressure must be verified through an approved hydraulic calculation.

24. Can a PSKDWG monitor be used with foam solution?

Foam compatibility is not confirmed in the available product information. Do not use foam solution without written confirmation covering the selected model, foam type, concentration, seals, materials, nozzle performance, and system configuration.

25. Are the PSKDWG explosion-proof monitors suitable for outdoor installation?

Outdoor suitability and the exact ingress-protection rating are not confirmed in the available information. Verify weather protection, corrosion resistance, enclosure rating, drainage, temperature exposure, and cable-entry protection for the intended site.

26. What must be checked before commissioning a PSKDWG explosion-proof water monitor?

Check the selected model, rated flow, working pressure, explosion-protection marking, hazardous-area compatibility, mounting security, grounding, cable entries, electrical seals, rotation clearance, control direction, water jet and fog functions, leakage, and operation-panel communication.

27. Can a PSKDWG monitor be opened or serviced while energized in a hazardous area?

Do not open, disconnect, or service explosion-protected electrical components while energized or while a hazardous atmosphere may be present. Isolation, gas testing, work permits, and servicing must follow the product requirements, site procedures, and local regulations.

28. How often should PSKDWG explosion-proof fixed water monitors be inspected and maintained?

Product-based maintenance should include regular movement and discharge tests, inspection of explosion-proof enclosures and cable entries, grounding checks, remote-control testing, cleaning, and lubrication where specified. The actual schedule must follow local regulations, the approved system design, hazardous-area requirements, site conditions, and the approved maintenance plan.

Free Preliminary System Drawings

Working on a project budget without a system layout? FireMarket provides free preliminary drawings to help you estimate equipment quantities and costs.

Request Free Preliminary Drawings

Related Products