Product Structure & Key Zones
Five construction details of the ZDMS0.6/10S-LZⅢ compact automatic fire monitor.
Integrated Control Valve
The LZⅢ configuration incorporates its water-control valve within the monitor assembly, reducing the need for a separately mounted external valve.
Sealed Protective Housing
Enclosed construction helps shield the operating mechanism from dust and splashing water. A built-in filter is identified in the manufacturer’s product information.
12345
Rotating Cable Arrangement
The compact rotating design is intended to limit cable twisting during horizontal movement. Confirm the supplied slip-ring configuration on the final technical drawing.
Short Nozzle Geometry
The nozzle remains within the compact housing envelope, helping reduce the risk of contact with nearby structures during rotation.
Fire-Source Detection Assembly
Thermal-imaging-based fire-source positioning is specified for this configuration. Sensor type and exact positioning are subject to the selected variant.
Numbered markers illustrate feature areas; internal valve and rotating electrical components are not visible in the exterior photograph. Use the approved manufacturer drawings to identify their exact locations.
Automatic Detection & Discharge
Detect Heat Source
Fire-source sensing initiates a search when the configured detection conditions are met.
Locate & Track Fire
The configured sensing assembly locates the fire source and can update the target position as it changes.
Pancut Air
The monitor adjusts its orientation to direct the nozzle towards the located fire source.
Halakan Secara Automatik
After the required control conditions and operator procedures are satisfied, the water-supply system enables discharge.
Illustrative operating sequence. Detection technology, control permissions and automatic discharge behavior depend on the selected configuration and commissioning settings. Images are conceptual illustrations, not exact component diagrams.
Need a system reference layout?
Ask FireMarket for a free preliminary design.
Pengecaman Kebakaran & Sasaran
Multi-sensor fire detection for more precise targeting and reduced false triggers.
3-in-1 Precision Detection & Dynamic Tracking
UV, infrared and visual inputs support fire-source localization, with moving-fire tracking available on supported configurations.
FireMarket 3-in-1 Recognition
Multiple sensing inputs help verify the fire location before discharge.
Single-Cue Recognition
Unverified visual cues may lead to false detection and unintended discharge.
✕ False Trigger Examples
Flames on a Digital Screen
A flame video is mistaken for a real fire, causing unwanted discharge.
Red LED Warning Light
A warning light is mistaken for a flame, triggering an unwanted water discharge.
Illustrative false-trigger scenarios. Actual discharge depends on the configured detection and release logic.
Parameter Teknikal
| Model | ZDMS0.6/10S-LZⅢ |
|---|---|
| Kadar Aliran | 10 L/s |
| Jejari perlindungan | 20 m |
| Jejari pemantauan | 40 m |
| Ketinggian pemasangan | 6–15 m |
| Tekanan operasi | 0.6–0.8 MPa |
| Masa pengesanan | ≤ 30 s |
Integrasi sistem
Pairs with fire-water supply, field controls and a central control host for monitored, controlled water discharge and multi-monitor projects.

Sistem Bekalan Air
Tank · Pump · Pipework

Kotak Kawalan Elektrik
Electrical control

Panel Operasi Tapak
On-site operation

Hos Kawalan Pusat
Pemantauan Berpusat
✓Multi-monitor configurations for larger projects.
✓Accessories and environment requirements reviewed during selection.
Illustrative overview only. Red line shows system association, not piping or wiring order; follow the manufacturer’s drawings for installation.